文献速递神经MR

应用基于蛋白质的酰胺质子转移磁共振成像鉴别单发脑转移瘤与胶质母细胞瘤

Applying protein-based amide proton transfer MR imaging to distinguish solitary brain metastases from glioblastoma.
PubMed 文献 · Eur Radiol · 2017-05-22

研究纳入45例单发脑转移瘤(SBM)和43例胶质母细胞瘤(GBM)患者,于临床干预前行常规及酰胺质子转移加权(APTw)序列检查,比较肿瘤核心与瘤周脑区(PBZ)的APTw及相对APTw参数。肿瘤核心各参数在两组间无显著差异,但PBZ各参数SBM组显著低于GBM组;APTwmin鉴别两组曲线下面积0.905、准确率85.2%。结论认为APTw磁共振成像可用于无创鉴别SBM与GBM。

要点

  • 肿瘤核心区APTw及rAPTw各参数在单发脑转移瘤与胶质母细胞瘤间无显著差异。
  • 瘤周脑区APTw及rAPTw各参数单发脑转移瘤组显著低于胶质母细胞瘤组(P<0.001)。
  • APTwmin为鉴别两者最佳参数,曲线下面积0.905、准确率85.2%。

核心结论

  • 酰胺质子转移加权磁共振成像作为一种无创影像方法,可用于鉴别单发脑转移瘤与胶质母细胞瘤。

研究设计与样本

  • 研究纳入45例单发脑转移瘤患者和43例胶质母细胞瘤患者,于临床干预前行常规及APTw序列检查,比较肿瘤核心与瘤周脑区的APTw及rAPTw参数,并以受试者工作特征曲线评估最佳鉴别参数。

关键影像表现/征象

  • 肿瘤核心区APTwmax、APTwmin、APTwmean、rAPTwmax、rAPTwmin、rAPTwmean在单发脑转移瘤组与胶质母细胞瘤组间无显著差异(P分别为0.141、0.361、0.221、0.305、0.578、0.448)。
  • 瘤周脑区APTwmax、APTwmin、APTwmean、rAPTwmax、rAPTwmin、rAPTwmean在单发脑转移瘤组均显著低于胶质母细胞瘤组(P<0.001)。

诊断标准与关键数值

  • 以APTwmin鉴别单发脑转移瘤与胶质母细胞瘤,曲线下面积0.905、准确率85.2%。

临床应用与阅片要点

  • 阅片时可关注瘤周脑区的APTw及rAPTw参数,单发脑转移瘤组该区域各参数显著低于胶质母细胞瘤组。
  • 肿瘤核心区APTw及rAPTw参数在两组间无显著差异,不宜单独依据肿瘤核心参数鉴别两者。
  • APTwmin为鉴别单发脑转移瘤与胶质母细胞瘤的最佳参数,曲线下面积0.905、准确率85.2%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine the utility of amide proton transfer-weighted (APTw) MR imaging in distinguishing solitary brain metastases (SBMs) from glioblastomas (GBMs).

METHODS: Forty-five patients with SBMs and 43 patients with GBMs underwent conventional and APT-weighted sequences before clinical intervention. The APTw parameters and relative APTw (rAPTw) parameters in the tumour core and the peritumoral brain zone (PBZ) were obtained and compared between SBMs and GBMs. The receiver-operating characteristic (ROC) curve was used to assess the best parameter for distinguishing between the two groups.

RESULTS: The APTwmax, APTwmin, APTwmean, rAPTwmax, rAPTwmin or rAPTwmean values in the tumour core were not significantly different between the SBM and GBM groups (P = 0.141, 0.361, 0.221, 0.305, 0.578 and 0.448, respectively). However, the APTwmax, APTwmin, APTwmean, rAPTwmax, rAPTwmin or rAPTwmean values in the PBZ were significantly lower in the SBM group than in the GBM group (P < 0.001). The APTwmin values had the highest area under the ROC curve 0.905 and accuracy 85.2% in discriminating between the two neoplasms.

CONCLUSION: As a noninvasive imaging method, APT-weighted MR imaging can be used to distinguish SBMs from GBMs.

KEY POINTS: • APTw values in the tumour core were not different between SBMs and GBMs. • APTw values in peritumoral brain zone were lower in SBMs than in GBMs. • The APTw min was the best parameter to distinguish SBMs from GBMs.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Yu H, Lou H, Zou T, et al. Applying protein-based amide proton transfer MR imaging to distinguish solitary brain metastases from glioblastoma. Eur Radiol. 2017. PMID: 28534162. doi:10.1007/s00330-017-4867-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。