文献速递神经外周血管MRDSA

三维磁共振成像与数字减影血管造影诊断颅内动脉狭窄的比较

Comparison of 3D magnetic resonance imaging and digital subtraction angiography for intracranial artery stenosis.
PubMed 文献 · Eur Radiol · 2017-05-12

研究纳入43例颅内动脉狭窄患者共516条颅内动脉,均于1个月内接受3D HR-MRI与DSA检查,由两名阅片者独立诊断动脉粥样硬化、夹层、烟雾病和血管炎并测量管腔直径。3D HR-MRI诊断动脉粥样硬化的准确率、敏感度和阳性预测值优于DSA,阅片者诊断信心更高,狭窄程度与DSA相似但管腔直径测值更高。

要点

  • 3D HR-MRI诊断动脉粥样硬化的准确率、敏感度和阳性预测值优于DSA。
  • 3D HR-MRI的总体诊断信心高于DSA。
  • 3D HR-MRI与DSA评估的狭窄程度相似,但3D HR-MRI测得的管腔直径更高。

核心结论

  • 3D HR-MRI可能有助于评估动脉粥样硬化,在整个Willis环范围内诊断信心优于DSA,狭窄测量与DSA相当。

研究设计与样本

  • 研究纳入43例颅内动脉狭窄患者的516条颅内动脉,均于1个月内接受3D HR-MRI和DSA检查,以临床-影像学诊断作为参考标准。

诊断标准与关键数值

  • 3D HR-MRI诊断动脉粥样硬化的准确率优于DSA(P = .03-.003)。
  • 3D HR-MRI诊断动脉粥样硬化的敏感度优于DSA(P = .006-.01)。
  • 3D HR-MRI诊断动脉粥样硬化的阳性预测值优于DSA(P ≤ .001-.006)。
  • 阅片者1使用3D HR-MRI的诊断信心高于DSA(P ≤ .001-.007),阅片者2使用3D HR-MRI的诊断信心高于DSA(P ≤ .001-.015)。
  • 3D HR-MRI与DSA评估的狭窄程度相似(P > .05),3D HR-MRI测得的管腔直径高于DSA(P < .05)。

临床应用与阅片要点

  • 作者认为3D HR-MRI可能有助于评估动脉粥样硬化,在整个Willis环范围内诊断信心优于DSA且狭窄测量与DSA相当。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare three-dimensional high-resolution magnetic resonance imaging (3D HR-MRI) and digital subtraction angiography (DSA) for diagnosing and evaluating stenosis in the entire circle of Willis.

METHODS: The study included 516 intracranial arteries from 43 patients with intracranial artery stenosis (ICAS) who underwent both 3D HR-MRI and DSA within 1 month. Two readers independently diagnosed atherosclerosis, dissection, moyamoya disease and vasculitis, rated their diagnostic confidence for each vessel and measured the luminal diameters. Reference standard was made from clinico-radiologic diagnosis. Diagnostic accuracy, diagnostic confidence, the degree of stenosis and luminal diameter were assessed and compared between both modalities.

RESULTS: For atherosclerosis, 3D HR-MRI showed better diagnostic accuracy (P = .03-.003), sensitivity (P = .006-.01) and positive predictive value (P ≤ .001-.006) compared to DSA. Overall, the readers were more confident of their diagnosis of ICAS when using 3D HR-MRI (reader 1, P ≤ .001-.007; reader 2, P ≤ .001-.015). 3D HR-MRI showed similar degree of stenosis (P > .05) and higher luminal diameter (P < .05) compared to DSA.

CONCLUSIONS: 3D HR-MRI might be useful to evaluate atherosclerosis, with better diagnostic confidence and comparable stenosis measurement compared to DSA in the entire circle of Willis.

KEY POINTS: • 3D HR-MRI showed better diagnostic accuracy for atherosclerosiscompared to DSA • 3D HR-MRI showed better overall diagnostic confidence for stenosiscompared to DSA • 3D HR-MRI and DSA showed similar degree of stenosis.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Park JE, Jung SC, Lee SH, et al. Comparison of 3D magnetic resonance imaging and digital subtraction angiography for intracranial artery stenosis. Eur Radiol. 2017. PMID: 28500366. doi:10.1007/s00330-017-4860-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。