文献速递泌尿生殖儿科影像MR

儿童移植肾扩散张量成像与组织病理学相关性的初步研究

Pilot Study of Renal Diffusion Tensor Imaging as a Correlate to Histopathology in Pediatric Renal Allografts.
PubMed 文献 · AJR Am J Roentgenol · 2017-04-05

前瞻性纳入16例儿童移植肾受体,在同日活检前行扩散张量成像,评估皮质与髓质各向异性分数(FA)与Banff组织病理学评分的关系;髓质FA与肾小管炎、间质炎症、肾小管萎缩及间质纤维化呈负相关,皮质FA与管周毛细血管炎负相关,且b值800 s/mm²时髓质FA在活检结果改变临床处理组与未改变组间存在统计学差异。

要点

  • 髓质FA与肾小管炎(t)、间质炎症(i)、肾小管萎缩(ct)及间质纤维化(ci)评分呈负相关。
  • 皮质FA与管周毛细血管炎(ptc)评分呈负相关。
  • b值800 s/mm²时,活检改变临床处理组髓质FA均值0.262,未改变组0.333,组间有统计学差异。

核心结论

  • FA是若干重要移植肾组织病理学评分的无创相关指标,可能是评估儿童移植肾受体移植肾健康的无创方法。

研究设计与样本

  • 前瞻性研究,纳入16例儿童移植肾受体,于2014年10月至2016年1月在同日移植肾活检前行扩散张量成像(DTI)。

诊断标准与关键数值

  • 髓质FA与肾小管炎(Banff t评分)呈直接负相关,p < 0.04。
  • 髓质FA与间质炎症(i评分)呈负相关,p < 0.005。
  • 髓质FA与肾小管萎缩(ct评分)呈负相关,p < 0.002。
  • 髓质FA与间质纤维化(ci评分)呈负相关,p < 0.007。
  • 皮质FA与管周毛细血管炎(ptc评分)呈负相关,p < 0.02。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Fractional anisotropy (FA) is a measure of molecular motion obtained from diffusion tensor imaging (DTI). The objective of this study was to assess the use of FA as a noninvasive correlate of renal allograft histopathology.

SUBJECTS AND METHODS: Sixteen pediatric renal allograft recipients were imaged using DTI in a prospective study, between October 2014 and January 2016, before a same-day renal allograft biopsy. The Kendall tau correlation coefficient was used to assess the relationship between cortical and medullary FA values and several clinically important Banff renal allograft histopathology scores. The Mann-Whitney U test was also used to compare cortical and medullary FA values in the region of biopsy in patients whose biopsy results did and in those whose biopsy results did not change clinical management.

RESULTS: Medullary FA values had direct inverse correlation with several histopathology scores: tubulitis (designated "t" score in Banff pathologic classification, p < 0.04), interstitial inflammation (i score, p < 0.005), tubular atrophy (ct score, p < 0.002), and interstitial fibrosis (ci score, p < 0.007). Cortical FA values inversely correlated with peritubular capillaritis (ptc score, p < 0.02). Neither medullary nor cortical FA values correlated with glomerulitis (g score). At a b value of 800 s/mm2, medullary FA values of pediatric renal allograft recipients whose renal biopsies prompted a change in clinical management (mean ± SD at a b value of 800 s/mm2 = 0.262 ± 0.07; n = 9) were statistically different compared with the group whose biopsy results did not change clinical management (mean ± SD at a b value of 800 s/mm2 = 0.333 ± 0.06; n = 7) (p < 0.006).

CONCLUSION: FA is a noninvasive correlate of several important renal allograft histopathology scores and a potential noninvasive method of assessing renal allograft health in pediatric allograft recipients.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Li Y, Lee MM, Worters PW, et al. Pilot Study of Renal Diffusion Tensor Imaging as a Correlate to Histopathology in Pediatric Renal Allografts. AJR Am J Roentgenol. 2017. PMID: 28379715. doi:10.2214/AJR.16.17418

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。