患者旋转体位对骨盆侧位X线片上骨盆参数评估的影响
研究利用8名儿童和9名成人的骨盆CT重建侧位数字重建X线片,模拟5°、10°、15°、20°的轴向旋转并测量骨盆参数。结果显示观察者间变异随旋转角度增大,20°时骨盆入射角达4.4°、骶骨坡度达4.7°;旋转达10°时参数偏差超过可接受误差阈值。基于双股骨距离归一化建立的线性回归可估算轴向旋转(R²=0.834,p<0.0001),作者认为可据此剔除旋转超过10°的X线片。
要点
- 骨盆轴向旋转≥10°时,骨盆参数测量偏差超过可接受误差阈值。
- 20°旋转时观察者间变异:骨盆入射角4.4°、骶骨坡度4.7°,儿童与成人相似。
- 可用双股骨距离与矢状骨盆厚度比值估算轴向旋转,R²=0.834。
核心结论
- 患者摄片时的轴向旋转可在临床实践中估算,使医生能够剔除计算旋转超过10°的X线片。
研究设计与样本
- 从8名儿童和9名成人的骨盆CT扫描获取侧位数字重建X线片,模拟5°、10°、15°、20°轴向旋转并重建对应图像;由3名操作者各重复测量3次评估观察者内和观察者间变异,以0°位置为参照计算各旋转位置下临床参数的偏差。
诊断标准与关键数值
- 观察者间变异随轴向旋转增大,儿童与成人相似;20°旋转时骨盆入射角观察者间变异达4.4°、骶骨坡度达4.7°;旋转达10°时放射学参数偏差超过可接受误差阈值;线性回归(R²=0.834,p<0.0001)基于双股骨距离归一化至矢状骨盆厚度估算轴向旋转。
临床应用与阅片要点
- 作者认为可在临床实践中估算患者摄片时的轴向旋转,并据此剔除计算旋转超过10°的X线片。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To estimate the effect of patients' axial rotation (AR) during pelvic radiograph acquisition, on the reliability and validity of sagittal pelvic parameters.
MATERIALS AND METHODS: Lateral digitally reconstructed radiographs (LDRRs) were obtained from the pelvic computed tomography (CT) scans of eight children and nine adults. Then, the AR of the pelvis was simulated and the corresponding LDRRs were reconstructed at 5°, 10°, 15°, and 20° of the AR. Pelvic parameters were measured digitally on each radiograph. Intra- and interobserver variability were evaluated at each AR position (three operators repeated the measurements three times each). The bias on each clinical parameter, in each AR position, was calculated relatively to the 0° position.
RESULTS: Interobserver variability increased similarly in children and adults with AR. It reached 4.4° for pelvic incidence and 4.7° for the sacral slope at 20° of AR. Biases on radiological parameters increased with AR and exceeded the acceptable threshold of errors when AR reached 10°. A linear regression was established (R2=0.834, p<0.0001) in order to estimate the AR of a patient on a lateral pelvic radiograph based on the measurement of the bifemoral distance normalized to the sagittal pelvic thickness.
CONCLUSIONS: AR of patients during radiograph acquisition can be estimated in clinical practice, which would allow physicians to discard any radiographs where the calculated AR exceeded 10°.
引用
- Assi A, Bakouny Z, Sauret C, et al. Influence of patient rotational malpositioning on pelvic parameters assessed on lateral radiographs. Clin Radiol. 2017. PMID: 28442141. doi:10.1016/j.crad.2017.03.021