3T三维双回波稳态序列评估髋关节软骨与盂唇:磁共振成像与术中数据的对比分析
本研究以45例接受髋关节镜手术患者为对象,对比3T磁共振径向重格式化三维双回波稳态(DESS)序列与术中数据,评估其对髋关节软骨和盂唇病变的诊断准确性。DESS检测软骨病变的敏感度96.7%、特异度75%、准确率93.7%,检测盂唇病变的敏感度98%、特异度76.2%、准确率95.9%,与术中评估一致性良好。
要点
- 3T径向重格式化3D DESS序列检测髋关节软骨病变敏感度96.7%、准确率93.7%。
- 该序列检测髋关节盂唇病变敏感度98%、准确率95.9%。
- MRI与术中评估相关程度中等,观察者间一致性极好。
核心结论
- 高分辨率3T三维DESS径向成像技术检测髋关节软骨和盂唇病变准确性高,观察者间一致性极好,MRI与术中评估相关程度中等。
研究设计与样本
- 研究纳入45例接受髋关节镜手术患者(平均年龄42±13.7岁),对比3T MRI径向重格式化DESS图像与术中数据,评估髋臼上半球软骨与盂唇及股骨头中央软骨。
关键影像表现/征象
- 评估部位包括髋臼上半球软骨与盂唇以及股骨头中央软骨。
- MRI与术中评估之间相关程度中等,观察者间一致性极好。
诊断标准与关键数值
- DESS检测软骨病变:敏感度96.7%、特异度75%、准确率93.7%,阳性预测值96%、阴性预测值78.9%。
- DESS检测盂唇病变:敏感度98%、特异度76.2%、准确率95.9%,阳性预测值97.5%、阴性预测值80%。
临床应用与阅片要点
- 高分辨率3D DESS径向成像可准确评估髋关节软骨与盂唇。
- 该序列准确性高,可能影响髋痛患者的治疗决策。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the diagnostic accuracy of a high-resolution, three-dimensional (3D) double-echo steady-state (DESS) sequence with radial imaging at 3 Tesla (T) for evaluating cartilage and labral alterations in the hip.
METHODS: Magnetic resonance imaging (MRI) data obtained at 3 T, including radially reformatted DESS images and intraoperative data of 45 patients (mean age 42 ± 13.7 years) who underwent hip arthroscopy, were compared. The acetabular cartilage and labrum of the upper hemisphere of the acetabulum and the central femoral head cartilage were evaluated. Sensitivity, specificity, accuracy, and negative and positive predictive values were determined.
RESULTS: Sensitivity, specificity and accuracy of the DESS technique were 96.7%, 75% and 93.7% for detecting cartilage lesions and 98%, 76.2% and 95.9% for detecting labral lesions. The positive and negative predictive values for detecting or ruling out cartilage lesions were 96% and 78.9%. For labral lesions, the positive and negative predictive values were 97.5% and 80%.
CONCLUSION: A high-resolution, 3D DESS technique with radial imaging at 3 T demonstrated high accuracy for detecting hip cartilage and labral lesions with excellent interobserver agreement and moderate correlation between MRI and intraoperative assessment.
KEY POINTS: • High-resolution, 3D DESS with radial imaging allows accurate cartilage and labrum evaluation. • DESS demonstrated high sensitivity, specificity, accuracy for detecting cartilage and labral lesions. • Highly accurate sequence may influence treatment decisions in patients with hip pain.
引用
- Schleich C, Hesper T, Hosalkar HS, et al. 3D double-echo steady-state sequence assessment of hip joint cartilage and labrum at 3 Tesla: comparative analysis of magnetic resonance imaging and intraoperative data. Eur Radiol. 2017. PMID: 28432505. doi:10.1007/s00330-017-4834-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。