膝关节内侧间室骨关节炎患者定量骨SPECT/CT的最大标准化摄取值
本研究纳入26例因膝关节内侧间室骨关节炎行手术的患者,术前接受锝-99m羟亚甲基二膦酸盐定量骨SPECT/CT检查,计算SUVmax,并与SPECT/CT视觉分级、Kellgren-Lawrence评分、MRI评分及症状评分进行相关性分析。结果显示手术侧膝关节内侧间室SUVmax高于非手术侧(14.1±6.1 vs 5.3±4.4,p<0.0001),且SUVmax与SPECT/CT视觉分级、KL评分及MRI评分显著相关,但与患者症状评分无相关性。作者认为定量骨SPECT/CT是客观评估膝关节骨关节炎的有前景的影像技术。
要点
- 手术侧膝关节内侧间室SUVmax为14.1±6.1,高于非手术侧的5.3±4.4(p<0.0001)。
- 内侧间室SUVmax与SPECT/CT视觉分级(rho=0.794)、KL评分(rho=0.703)及MRI评分(rho=0.714-0.808)显著相关。
- SUVmax及其他影像参数与患者症状评分无相关性(p>0.05)。
核心结论
- 定量骨SPECT/CT的SUVmax与膝关节内侧间室骨关节炎严重程度的传统影像参数高度相关,是客观评估膝关节骨关节炎的有前景的影像技术。
研究设计与样本
- 研究纳入26例因膝关节内侧间室骨关节炎行手术的患者(男:女=2:24,年龄55.3±5.8岁),术前接受锝-99m羟亚甲基二膦酸盐定量骨SPECT/CT检查,SUVmax用专用定量软件计算,并评估SPECT/CT视觉分级、Kellgren-Lawrence评分、MRI评分(n=22)及患者症状评分。
诊断标准与关键数值
- 手术侧膝关节(n=34)内侧间室SUVmax为14.1±6.1,非手术侧膝关节(n=18)为5.3±4.4,手术侧高于非手术侧(p<0.0001)。
- 内侧间室SUVmax与SPECT/CT视觉分级显著相关(rho=0.794,p<0.0001)。
- 内侧间室SUVmax与Kellgren-Lawrence评分显著相关(rho=0.703,p<0.0001)。
- 内侧间室SUVmax与MRI评分显著相关(rho=0.714-0.808,p≤0.0002)。
- SUVmax及其他影像参数与患者症状评分无相关性(p>0.05)。
临床应用与阅片要点
- 定量骨SPECT/CT的SUVmax可用于客观评估膝关节内侧间室骨关节炎的严重程度,与SPECT/CT视觉分级、KL评分及MRI评分高度相关。
- SUVmax及其他影像参数与患者症状评分无相关性,解读时应结合影像参数而非仅凭症状评分。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the correlation between the maximum standardised uptake value (SUVmax) from bone single-photon-emission computed tomography/computed tomography (SPECT/CT) and other imaging parameters for medial compartment osteoarthritis (OA) of the knee.
MATERIALS AND METHODS: Patients (n=26; male:female=2:24; age, 55.3±5.8 years) underwent quantitative knee SPECT/CT using technetium-99m (Tc-99m) hydroxymethylene diphosphonate (HDP) before surgical operation for medial OA of the knee. SUVmax was calculated using dedicated quantitative software. Visual grades of tracer uptake on bone SPECT/CT and Kellgren-Lawrence (KL) OA scores on plain radiographs were assessed using a five-point scale. Magnetic resonance imaging (MRI) scores (n=22) and patient symptom scores were also assessed.
RESULTS: The operated knees (n=34) had a greater SUVmax than the non-operated knees (n=18) in the medial compartment (14.1±6.1 versus 5.3±4.4, p<0.0001). In the medial compartment, the SUVmax was significantly correlated with SPECT/CT visual grades (rho=0.794, p<0.0001), KL scores (rho=0.703, p<0.0001), and MRI scores (rho=0.714-0.808, p≤0.0002); however, SUVmax and other imaging parameters were not correlated with patient symptom scores (p>0.05).
CONCLUSIONS: The SUVmax of quantitative bone SPECT/CT was highly correlated with traditional imaging parameters for medial compartment OA severity of the knee. Quantitative bone SPECT/CT is a promising imaging technique for the objective assessment of knee OA.
引用
- Kim J, Lee HH, Kang Y, et al. Maximum standardised uptake value of quantitative bone SPECT/CT in patients with medial compartment osteoarthritis of the knee. Clin Radiol. 2017. PMID: 28400059. doi:10.1016/j.crad.2017.03.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。