文献速递骨肌介入CT

腰椎神经根周围超低剂量浸润:点扫描及其通过替代螺旋规划CT进一步降低剂量的潜力

Ultra-low-dose periradicular infiltration of the lumbar spine: spot scanning and its potential for further dose reduction by replacing helical planning CT.
PubMed 文献 · Radiol Med · 2017-04-20

研究比较点扫描与节段螺旋规划CT在CT引导下腰椎单部位神经根周围浸润中的剂量。点扫描组63例、螺旋规划CT对照组22例,中位DLP分别为0.80与6.50 mGy cm,总介入剂量中位DLP从8.90降至3.20 mGy cm(-64%),介入所需采集次数无显著差异,两组疼痛评分中位下降均为2分。作者推荐点扫描用于降低剂量。

要点

  • 点扫描规划中位DLP为0.80 mGy cm,螺旋规划CT为6.50 mGy cm。
  • 总介入剂量中位DLP从8.90降至3.20 mGy cm,降低64%。
  • 两组介入所需采集次数无显著差异,疼痛评分中位下降均为2分。

核心结论

  • 专用点扫描规划使介入总中位有效剂量降低超过64%,且未增加介入过程中所需图像数量;两种方法均实现显著疼痛缓解;作者推荐点扫描用于降低剂量。

研究设计与样本

  • 回顾性对照研究,共85例患者接受CT引导下腰椎单部位神经根周围治疗,无既往影像可用于规划;组I 63例采用新型专用点扫描技术,组II 22例采用常规节段螺旋规划CT作为对照。

诊断标准与关键数值

  • 规划扫描中位DLP:点扫描组0.80 mGy cm vs 螺旋规划CT组6.50 mGy cm。
  • 规划扫描对总介入剂量的贡献从73%降至25%。
  • 总介入剂量中位DLP从8.90 mGy cm降至3.20 mGy cm(-64%)。
  • 介入所需采集中位DLP:组I 2.40 mGy cm vs 组II 2.35 mGy cm,无显著差异。
  • 两组疼痛数字评分表中位下降均为2分。

临床应用与阅片要点

  • 作者推荐采用专用点扫描进行规划以降低介入总剂量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Computed tomography (CT)-guided periradicular infiltration has become an accepted procedure for treating radiculopathy-associated low back pain. The purpose of this study is to compare spot scanning and segmental helical planning CT in terms of dose reduction.

MATERIALS AND METHODS: Eighty-five patients underwent CT-guided single-site lumbar periradicular therapy. Prior imaging was not available for planning. Sixty-three patients were examined with a new dedicated spot scanning technique (group I), and twenty-two patients underwent conventional segmental planning CT examinations with helical image acquisition serving as controls (group II). Examinations were reviewed retrospectively for dose-length product (DLP) and number of acquisitions required for intervention. Pain reduction accomplished with the intervention was recorded for quality assurance.

RESULTS: Median DLP was 0.80 mGy cm for spot scanning versus 6.50 mGy cm for segmental planning CT. Thus, the contribution of the planning scan to the total interventional dose decreased from 73 to 25%. As a result, the total interventional dose was reduced significantly from a median DLP of 8.90 mGy cm to 3.20 mGy cm (-64%). Acquisitions required during the intervention had a median DLP of 2.40 mGy cm for group I and 2.35 mGy cm for group II, showing no significant difference. Median pain reduction in both groups was two points on the numeric rating scale.

CONCLUSION: Dedicated spot scanning for planning reduced the total median effective dose of the intervention by more than 64% without increasing the number of images required during the interventional procedure. Significant pain reduction was achieved with both approaches. Spot scanning is recommended for dose reduction.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Elsholtz FHJ, Schaafs LA, Erxleben C, et al. Ultra-low-dose periradicular infiltration of the lumbar spine: spot scanning and its potential for further dose reduction by replacing helical planning CT. Radiol Med. 2017. PMID: 28429208. doi:10.1007/s11547-017-0766-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。