基于径向采样、压缩感知与并行成像的脂肪/水分离高时空分辨率乳腺全面动态对比增强3D磁共振成像
本前瞻性研究纳入24例连续患者,评估Dixon-RAVE(结合径向采样、基于模型的脂肪/水分离、压缩感知与并行成像)用于乳腺全面动态对比增强3D MRI的可行性。结果显示Dixon-RAVE在脂肪抑制程度上显著高于常规VIBE,图像质量虽较低但达到可接受或更好诊断质量(评分≥3),作者认为其可作为一站式全面T1加权乳腺MRI方法。
要点
- Dixon-RAVE脂肪抑制评分显著高于VIBE:压脂预扫4.25 vs 3.67,动态压脂4.10 vs 3.46(P<0.001)。
- Dixon-RAVE图像质量评分低于VIBE但均≥3分,达到可接受或更好诊断质量。
- Dixon-RAVE一次扫描可重建多种对比图像,缩短总扫描时间。
核心结论
- Dixon-RAVE可作为一站式全面T1加权乳腺MRI方法,具有诊断级图像质量、高时空分辨率、缩短总扫描时间及优于常规成像的脂肪抑制。
研究设计与样本
- 健康保险流通与责任法案合规的前瞻性研究,纳入24例连续患者,行双侧乳腺MRI;先采集常规压脂与非压脂预扫T1加权VIBE,注射对比剂后行1次连续Dixon-RAVE扫描,随即采集4次常规压脂VIBE扫描。
诊断标准与关键数值
- 两名放射科医师独立采用5点李克特量表评分图像质量、纤维腺体组织与脂肪的区分度及脂肪抑制程度;Dixon-RAVE脂肪抑制评分显著高于VIBE(压脂预扫4.25 vs 3.67,动态压脂4.10 vs 3.46,P<0.001);图像质量评分Dixon-RAVE低于VIBE(压脂预扫3.56 vs 3.67,P=0.490;非压脂预扫3.54 vs 3.88,P=0.009;动态压脂3.06 vs 3.67,P<0.001),但均≥3分达到可接受或更好诊断质量;纤维腺体组织区分度评分Dixon-RAVE在压脂预扫显著高于VIBE(4.23 vs 3.85,P=0.044),在非压脂预扫低于VIBE(3.98 vs 4.25,P=0.054),在动态压脂与VIBE相近(3.90 vs 3.85,P=0.845)。
临床应用与阅片要点
- Dixon-RAVE一次扫描可重建与常规VIBE相当的多种图像对比,脂肪抑制程度更高,图像质量虽较低但达到诊断可接受水平,作者认为可作为一站式全面T1加权乳腺MRI方法。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to assess the applicability of Dixon radial volumetric encoding (Dixon-RAVE) for comprehensive dynamic contrast-enhanced 3D magnetic resonance imaging (MRI) of the breast using a combination of radial sampling, model-based fat/water separation, compressed sensing, and parallel imaging.
MATERIALS AND METHODS: In this Health Insurance Portability and Accountability Act-compliant prospective study, 24 consecutive patients underwent bilateral breast MRI, including both conventional fat-suppressed and non-fat-suppressed precontrast T1-weighted volumetric interpolated breath-hold examination (VIBE). Afterward, 1 continuous Dixon-RAVE scan was performed with the proposed approach while the contrast agent was injected. This scan was immediately followed by the acquisition of 4 conventional fat-saturated VIBE scans. From the comprehensive Dixon-RAVE data set, different image contrasts were reconstructed that are comparable to the separate conventional VIBE scans.Two radiologists independently rated image quality, conspicuity of fibroglandular tissue from fat (FG), and degree of fat suppression (FS) on a 5-point Likert-type scale for the following 3 comparisons: precontrast fat-suppressed (pre-FS), precontrast non-fat-suppressed (pre-NFS), and dynamic fat-suppressed (dyn-FS) images.
RESULTS: When scores were averaged over readers, Dixon-RAVE achieved significantly higher (P < 0.001) degree of fat suppression compared with VIBE, for both pre-FS (4.25 vs 3.67) and dyn-FS (4.10 vs 3.46) images. Although Dixon-RAVE had lower image quality score compared with VIBE for the pre-FS (3.56 vs 3.67, P = 0.490), the pre-NFS (3.54 vs 3.88, P = 0.009), and the dyn-FS images (3.06 vs 3.67, P < 0.001), acceptable or better diagnostic quality was achieved (score ≥ 3). The FG score for Dixon-RAVE in comparison to VIBE was significantly higher for the pre-FS image (4.23 vs 3.85, P = 0.044), lower for the pre-NFS image (3.98 vs 4.25, P = 0.054), and higher for the dynamic fat-suppressed image (3.90 vs 3.85, P = 0.845).
CONCLUSIONS: Dixon-RAVE can serve as a one-stop-shop approach for comprehensive T1-weighted breast MRI with diagnostic image quality, high spatiotemporal resolution, reduced overall scan time, and improved fat suppression compared with conventional imaging.
引用
- Benkert T, Block KT, Heller S, et al. Comprehensive Dynamic Contrast-Enhanced 3D Magnetic Resonance Imaging of the Breast With Fat/Water Separation and High Spatiotemporal Resolution Using Radial Sampling, Compressed Sensing, and Parallel Imaging. Invest Radiol. 2017. PMID: 28398929. doi:10.1097/RLI.0000000000000375
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。