乳腺癌患者腋窝淋巴结的微泡检测与超声引导下真空辅助活检
研究评估微泡引导真空辅助活检(VAB)检测前哨淋巴结(SLN)的可行性及转移检出敏感度,并观察患者体验与对后续腋窝手术的影响。共招募139例患者,Part 2 中100例可分析,82例(82%)活检成功,转移检出敏感度为58.8%(95%CI 32.9%, 81.6%)。VAB对后续手术SLN活检造成干扰,48%患者报告中度或重度干扰,8.3%完全失败。
要点
- 微泡引导VAB技术可行,82%患者活检成功。
- 转移检出敏感度58.8%(95%CI 32.9%, 81.6%)。
- VAB对后续手术SLN活检有不良影响,48%中度或重度干扰,8.3%完全失败。
核心结论
- 对微泡检测的SLN进行VAB是可行的;转移检出敏感度尚可,但对后续手术的不良影响显著。
研究设计与样本
- 前瞻性研究,分两部分:Part 1(36例)建立超声微泡造影检测SLN技术,Part 2(103例)微泡检测SLN后行13G VAB,所有患者随后手术组织学对照;Part 2 中100例纳入分析。
关键影像表现/征象
- 超声微泡造影用于检测SLN。
- 13G VAB用于微泡检测到的SLN活检。
诊断标准与关键数值
- Part 2 中100例可分析患者,82例(82%)VAB活检成功。
- VAB检测转移的敏感度为58.8%(95%CI 32.9%, 81.6%)。
临床应用与阅片要点
- VAB操作总体耐受良好。
- VAB对后续手术SLN活检有不良干扰,48%患者外科医生报告中度或重度干扰,8.3%患者SLNB完全失败。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIMS: To assess the feasibility of undertaking microbubble-guided vacuum-assisted biopsy (VAB) of the sentinel lymph node (SLN) and determine its sensitivity in detecting metastases. Patient experience and the impact of VAB on subsequent axillary surgery were also evaluated.
MATERIALS AND METHODS: Patients with a normal axillary ultrasound or benign core biopsy planned for surgical SLN biopsy were recruited. Part 1 of the study was used to establish the technique of ultrasound microbubble contrast to detect the SLN. In Part 2 microbubble detection of the SLN was followed by 13 G VAB. All patients subsequently had surgical histological correlation.
RESULTS: One hundred and thirty-nine patients were recruited: 36 to Part 1 and 103 to Part 2. Of the 100 patients in Part 2 included for analysis, 82 (82%) underwent successful biopsy. Sensitivity for detecting metastases was 58.8% (95% confidence interval: 32.9%, 81.6%). The procedure was generally well tolerated; however, VAB interfered adversely with subsequent surgical SLN biopsy with surgeons reporting moderate or severe interference in 48% of patients and an additional 8.3% with complete failure of SLNB.
CONCLUSION: It is possible to perform VAB of microbubble-detected SLNs. Although the sensitivity for detecting metastases was reasonable, the adverse effect on subsequent surgery was significant.
引用
- Britton P, Willsher P, Taylor K, et al. Microbubble detection and ultrasound-guided vacuum-assisted biopsy of axillary lymph nodes in patients with breast cancer. Clin Radiol. 2017. PMID: 28427743. doi:10.1016/j.crad.2017.03.011