超声BI-RADS 3-5类实性肿块的阳性预测值:一项独立阅片者研究
该回顾性研究纳入4名美国与4名非美国阅片者,对374例经活检证实的超声实性肿块进行BI-RADS分类,并在提供指南前后分别评估阳性预测值。结果显示PPV随BI-RADS类别升高而增加,仅4c类达到ACR基准,4a类PPV过高;指南未显著改善整体表现,常规使用BI-RADS 4亚分类者表现优于非使用者。
要点
- 超声BI-RADS 4a类PPV过高(指南前27.3%、指南后30.5%),未达ACR基准。
- 仅BI-RADS 4c类达到ACR PPV基准,3、4a、4b、5类均未达标。
- 常规使用BI-RADS 4亚分类的阅片者表现优于非使用者。
核心结论
- 指南前后阅片者PPV均随BI-RADS类别升高而增加;ACR PPV基准仅在4c类达到,其他类别未达到,尤其是4a亚类PPV过高;常规使用BI-RADS 4亚分类者表现优于非使用者。
研究设计与样本
- 回顾性、经IRB批准的研究,纳入4名美国与4名非美国阅片者,对374例经活检证实的超声肿块图像进行BI-RADS分类,并在提供指南前后分别评估。
诊断标准与关键数值
- 指南前后PPV:BI-RADS 3类6.0%与4.4%,4a类27.3%与30.5%,4b类49.9%与51.5%,4c类69.0%与67.4%,5类79.3%与80.1%。
- 仅BI-RADS 4c类达到ACR PPV基准,3、4a、4b、5类未达到。
- 常规BI-RADS 4亚分类使用者未达基准的差距小于非常规使用者。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: We assessed multiple readers' positive predictive values (PPVs) for ACR BI-RADS 3, 4a, 4b, 4c and 5 masses on ultrasound (US) pre- and post-proposed guidelines.
METHODS: This retrospective, IRB-approved study included four American and four non-American readers who assigned BI-RADS categories for US images of 374 biopsy-proved masses. Readers were offered guidelines and re-classified the masses. We assessed readers' abilities to achieve ACR benchmarks BI-RADS categories pre- and post-guidelines.
RESULTS: PPVs increased with BI-RADS category. The PPVs pre- and post-guidelines were 6.0% and 4.4% for category 3, 27.3% and 30.5% for category 4a, 49.9% and 51.5% for category 4b, 69.0% and 67.4% for category 4c, and 79.3% and 80.1% for category 5. Readers achieved the PPV benchmark for category 4c, but not for categories 3, 4a, 4b and 5, with no significant improvement after guidelines. Regular BI-RADS 4 subcategory users missed benchmarks by less than non-regular users.
CONCLUSION: Pre- and post-guidelines, readers' PPVs increased with BI-RADS categories, ACR PPV benchmarks were achieved in category 4c, missed in other categories, especially in the critical 4a subcategory, where the PPV was too high. BI-RADS 4 subcategory users performed better than non-users.
KEY POINTS: • Readers failed to achieve benchmarks for BI-RADS 4 subcategories, especially 4a. • USA and Brazilian readers performed similarly in ACR BI-RADS 4 subcategorization. • Proposed guidelines did not improve overall, USA or Brazilian reader performance. • Regularly BI-RADS 4 subcategory users performed better than did non-users. • US features distinguished between benign and malignant, not BI-RADS 4 subcategories.
引用
- Stavros AT, Freitas AG, deMello GGN, et al. Ultrasound positive predictive values by BI-RADS categories 3-5 for solid masses: An independent reader study. Eur Radiol. 2017. PMID: 28396996. doi:10.1007/s00330-017-4835-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。