国际子宫内膜分析组彩色评分评估子宫内膜血流量的可重复性:基于存储的三维容积
本研究评估国际子宫内膜肿瘤分析(IETA)组彩色评分在三维容积中评估子宫内膜血管化的观察者内和观察者间可重复性。8名检查者(4名熟练检查者与4名妇产科受训者)对68个子宫内膜三维容积进行IETA彩色评分(1~4分),4周后重复。观察者内加权κ为0.84~0.91,观察者间加权κ为0.77~0.96,无论经验水平如何,可重复性均为好或很好。
要点
- IETA彩色评分基于三维容积评估子宫内膜血管化,观察者内加权κ为0.84~0.91,可重复性很好。
- 观察者间加权κ为0.77~0.96,无论检查者经验水平如何,可重复性均为好或很好。
- 评分采用断层超声成像,分级为1分无血管、2分低血管、3分中等血管、4分丰富血管。
核心结论
- 使用三维容积分配IETA彩色评分评估子宫内膜血管化的可重复性为好或很好,与检查者经验无关。
研究设计与样本
- 研究选取68个来自不同子宫内膜疾病女性的子宫内膜彩色多普勒三维容积,由8名检查者(4名熟练检查者与4名妇产科受训者)采用断层超声成像分配IETA彩色评分,4周后重复,计算加权κ指数。
诊断标准与关键数值
- IETA彩色评分分级:1分无血管化,2分低血管化,3分中等血管化,4分丰富血管化;观察者内加权κ为0.84~0.91,观察者间加权κ为0.77~0.96。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To estimate intraobserver and interobserver reproducibility for assigning an International Endometrial Tumor Analysis (IETA) group color score for endometrial vascularization on color Doppler imaging.
METHODS: Sixty-eight endometrial 3-dimensional volumes from endometrial color Doppler assessments of women with different endometrial disorders were evaluated by 8 different examiners (4 skilled examiners and 4 obstetric and gynecologic trainees). One skilled examiner who did not participate in the assessments selected the 68 volumes from a database to select a balanced number of each IETA score. Each examiner evaluated the 68 endometrial volumes to assign the IETA color score (1, absence of vascularization; 2, low vascularization; 3, moderate vascularization; or 4, abundant vascularization) using tomographic ultrasound imaging. The analysis was repeated 4 weeks later, and interobserver and intraobserver reproducibility was analyzed by calculating the weighted κ index. The second of the measurements made by each observer was used to estimate interobserver reproducibility.
RESULTS: The intraobserver reproducibility was very good for all examiners, with a weighted κ index ranging from 0.84 to 0.91. The interobserver reproducibility was good or very good for all estimated comparisons, with a weighted κ index ranging from 0.77 to 0.96, regardless of experience level.
CONCLUSIONS: The reproducibility of assigning the IETA color score for assessing endometrial vascularization using 3-dimensional volumes is good or very good regardless of the experience of the examiner.
引用
- Alcázar JL, Pascual MÁ, Ajossa S, et al. Reproducibility of the International Endometrial Analysis Group Color Score for Assigning the Amount of Flow Within the Endometrium Using Stored 3-Dimensional Volumes. J Ultrasound Med. 2017. PMID: 28449311. doi:10.7863/ultra.16.06002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。