文献速递泌尿生殖儿科影像US

声辐射力脉冲成像定量评估慢性肾病患儿肾实质弹性的初步结果

Acoustic Radiation Force Impulse Quantification in the Evaluation of Renal Parenchyma Elasticity in Pediatric Patients With Chronic Kidney Disease: Preliminary Results.
PubMed 文献 · J Ultrasound Med · 2017-04-08

前瞻性研究纳入38名健康志愿者和30例儿童慢性肾脏病患者,用声辐射力脉冲成像测量双肾剪切波速度。健康志愿者平均剪切波速度为2.21±0.34 m/s,慢性肾脏病各期均显著低于健康志愿者;预测慢性肾脏病的截断值为1.81 m/s,敏感度76.5%、特异度92.1%(AUC=0.870)。作者认为声辐射力脉冲成像可能是有助于检出儿童慢性肾脏病的工具。

要点

  • 儿童慢性肾脏病患者各期肾剪切波速度均显著低于健康志愿者。
  • 预测慢性肾脏病的剪切波速度截断值为1.81 m/s,敏感度76.5%、特异度92.1%。
  • 除5期外,声辐射力脉冲成像不能预测慢性肾脏病不同分期。

核心结论

  • 声辐射力脉冲成像可能是有助于检出儿童慢性肾脏病的工具。

研究设计与样本

  • 前瞻性研究,纳入38名健康志愿者和30例儿童慢性肾脏病患者,评估双肾剪切波速度。

关键影像表现/征象

  • 健康志愿者平均剪切波速度为2.21±0.34 m/s。
  • 慢性肾脏病1、2、3、4、5期剪切波速度分别为1.81±0.49、1.72±0.63、1.66±0.29、1.48±0.37、1.23±0.27 m/s。
  • 慢性肾脏病各期剪切波速度均显著低于健康志愿者。

诊断标准与关键数值

  • 预测慢性肾脏病的剪切波速度截断值为1.81 m/s,敏感度76.5%、特异度92.1%,AUC=0.870(95%CI 0.750-0.990;P<.001)。
  • 观察者间一致性组内相关系数为0.65(95%CI 0.34-0.83;P<.001)。

临床应用与阅片要点

  • 儿童慢性肾脏病肾实质剪切波速度低于健康儿童,阅片时可关注这一表现。
  • 声辐射力脉冲成像除5期外不能预测慢性肾脏病不同分期。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate renal parenchymal elasticity with acoustic radiation force impulse imaging in pediatric patients with chronic kidney disease (CKD) and compare with healthy volunteers.

METHODS: Thirty-eight healthy volunteers and 30 pediatric CKD patients were enrolled in this prospective study. The shear wave velocity (SW) values of both kidneys in CKD patients and healthy volunteers were evaluated.

RESULTS: The mean SW in healthy volunteers was 2.21 ± 0.34 m/s, whereas the same value was 1.81 ± 0.49, 1.72 ± 0.63, 1.66 ± 0.29, 1.48 ± 0.37, and 1.23 ± 0.27 for stages 1, 2, 3, 4, and 5 in CKD patients, respectively. The SW was significantly lower for each stage in the CKD patients compared with healthy volunteers. Acoustic radiation force impulse could not predict the different stages of CKD, with the exception of stage 5. The cut-off value for predicting CKD was 1.81 m/s; at this threshold, sensitivity was 76.5% and specificity was 92.1% (area under the curve = 0.870 [95% confidence interval: 0.750-0.990]; P < .001). Interobserver agreement expressed as intraclass coefficient correlation was 0.65 (95% confidence interval: 0.34 to 0.83; P < .001).

CONCLUSIONS: Acoustic radiation force impulse may be a potentially useful tool in detecting CKD in pediatric patients.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Bilgici MC, Bekci T, Genc G, et al. Acoustic Radiation Force Impulse Quantification in the Evaluation of Renal Parenchyma Elasticity in Pediatric Patients With Chronic Kidney Disease: Preliminary Results. J Ultrasound Med. 2017. PMID: 28390141. doi:10.7863/ultra.16.08033

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。