文献速递泌尿生殖腹部US

开放部分肾切除术中超声造影检测和表征肾肿块的可行性

Feasibility of Contrast-Enhanced Intraoperative Ultrasound for Detection and Characterization of Renal Mass Undergoing Open Partial Nephrectomy.
PubMed 文献 · J Ultrasound Med · 2017-04-08

本研究纳入10例已知肾肿块并计划行术中超声引导开放部分肾切除术的患者,由放射科医师在肾脏暴露后行术中超声造影。术中超声在11例中的10例成功获取,造影后图像质量可接受至优秀,未发现额外病灶,无不良事件,作者认为该技术可行且安全。

要点

  • 开放部分肾切除术中,放射科医师可在肾脏暴露后完成超声造影检查。
  • 造影后图像质量可接受至优秀,所有病灶均为实性,未发现额外病灶。
  • 10例患者均未记录不良事件,作者认为术中超声造影可行且安全。

核心结论

  • 在这项包含10例患者的可行性研究中,开放部分肾切除术中超声造影用于肾肿块的检测和表征是可行且安全的;由于术中超声可影响手术范围,超声造影可帮助术中检测和表征肾肿块以辅助手术规划/切除。

研究设计与样本

  • 可行性研究,研究人群为10例已知肾肿块并计划行术中超声引导开放部分肾切除术的患者,由外科医师分离并暴露肾脏后,放射科医师行术中超声造影检查(造影前和造影后),可行性定义为10例患者中8例成功完成术中超声造影成像。

关键影像表现/征象

  • 术中超声在11例中的10例成功获取用于肾肿块检测和表征,1例因困难手术相关的临床并发症在术中取消。
  • 肿瘤大小范围为1.3至4.2 cm,所有病灶均为实性。
  • 与基线影像相比,超声造影未发现额外病灶。
  • 造影后图像质量范围为可接受至优秀。

诊断标准与关键数值

  • 可行性定义为10例患者中8例成功完成术中超声造影成像。
  • 图像质量、病灶显著性/对比度、病灶血管性、形态和大小在造影前和造影后图像上评估并分级。

临床应用与阅片要点

  • 开放部分肾切除术中,外科医师分离并暴露肾脏后,可由放射科医师行术中超声造影检查。
  • 术中超声造影可用于帮助检测和表征肾肿块,以辅助术中手术规划/切除。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine the feasibility of obtaining intraoperative contrast-enhanced ultrasound (CEUS) imaging in patients undergoing open partial nephrectomy for renal cancer. We hypothesize that the study was feasible and the addition of CEUS would improve lesion identification and characterization.

METHODS: The study population consisted of 10 patients with known renal mass scheduled for intraoperative ultrasound-guided open partial nephrectomy. After dissection and exposure of the kidney by the surgeon, an intraoperative pre- and post-CEUS was performed by the radiologist. Feasibility was defined as successful imaging in 8 of 10 patients with intraoperative CEUS. Image quality, lesion conspicuity/contrast, lesion vascularity, morphology, and size were assessed and graded with pre- and post-contrast images.

RESULTS: Intraoperative ultrasound was successfully acquired in 10 of 11 patients for renal mass detection and characterization. One study was canceled intraoperatively as a result of clinical complications related to a difficult surgery. Tumor size ranged from 1.3 to 4.2 cm. All lesions were solid. No additional lesions were found on CEUS compared with baseline imaging. Image quality post-contrast ranged from acceptable to excellent. There were no adverse events recorded for all 10 patients.

CONCLUSIONS: In our feasibility study consisting of 10 patients, CEUS for detection and characterization of renal mass undergoing open partial nephrectomy was feasible and safe. Because intraoperative ultrasound during open partial nephrectomy can affect the extent of surgery, CEUS can be used to help detect and characterize renal mass for surgical planning/resection intraoperatively.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Le O, Wood C, Vikram R, et al. Feasibility of Contrast-Enhanced Intraoperative Ultrasound for Detection and Characterization of Renal Mass Undergoing Open Partial Nephrectomy. J Ultrasound Med. 2017. PMID: 28390143. doi:10.7863/ultra.16.07053

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。