前列腺癌:扩散加权MR成像检测与侵袭性评估——常规模型与峰度模型的比较
该回顾性研究纳入285例前列腺癌患者,术前行3.0-T前列腺MR扩散加权成像(含扩散峰度序列),比较表观扩散系数(ADC)与扩散峰度(K)在前列腺癌检测及分级评估中的价值。结果显示ADC与K高度相关(r=-0.82),诊断性能相似,在大多数病例中对各项结局一致,未显示扩散峰度成像相比标准扩散加权成像的明确附加价值。
要点
- ADC与K在前列腺癌与良性组织、不同Gleason评分组间均存在显著差异(P < .001)。
- 良性 vs 恶性组织ADC的AUC为0.921,显著高于K的0.902(P = .002)。
- Gleason评分分组间ADC与K的AUC相似(0.694–0.744,P > .15),未显示峰度成像的明确附加价值。
核心结论
- ADC与K高度相关,诊断性能相似,在大多数病例中对各项结局一致;这些观察未显示扩散峰度成像相比标准扩散加权成像在前列腺癌临床评估中的明确附加价值。
研究设计与样本
- 回顾性机构审查委员会批准的研究,豁免知情同意;285例前列腺癌患者,术前接受3.0-T相控阵线圈前列腺MR成像,包括扩散峰度序列(b值0、500、1000、1500、2000 sec/mm2);分别以最大b值1000和2000 sec/mm2推导ADC图和扩散峰度K图;在每个患者的主病灶和良性前列腺组织上放置感兴趣容积(VOI)获取平均ADC和K;采用配对t检验、方差分析、ROC分析和精确检验进行比较。
诊断标准与关键数值
- 良性 vs 恶性组织:ADC的AUC为0.921,K的AUC为0.902,ADC显著高于K(P = .002);GS ≤ 3+3 vs GS ≥ 3+4肿瘤:ADC与K的AUC为0.715–0.744,两者相似(P > .15);GS ≤ 3+4 vs GS ≥ 4+3肿瘤:ADC与K的AUC为0.694–0.720,两者相似(P > .15);ADC与K高度相关(r = -0.82;P < .001);在80.0%–88.6%的患者中ADC与K对各项结局一致;在不一致的患者中,ADC对GS ≤ 3+4 vs GS ≥ 4+3肿瘤的表现优于K(P = .016),其他结局两者相似(P > .136)。
临床应用与阅片要点
- 作者结论认为,这些观察未显示扩散峰度成像相比标准扩散加权成像在前列腺癌临床评估中的明确附加价值;原文未据此给出具体阅片或报告推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To compare standard diffusion-weighted (DW) imaging and diffusion kurtosis (DK) imaging for prostate cancer (PC) detection and characterization in a large patient cohort, with attention to the potential added value of DK imaging. Materials and Methods This retrospective institutional review board-approved study received a waiver of informed consent. Two hundred eighty-five patients with PC underwent 3.0-T phased-array coil prostate magnetic resonance (MR) imaging, including a DK imaging sequence (b values 0, 500, 1000, 1500, and 2000 sec/mm2) before prostatectomy. Maps of apparent diffusion coefficient (ADC) and diffusional kurtosis (K) were derived by using maximal b values of 1000 and 2000 sec/mm2, respectively. Mean ADC and K were obtained from volumes of interest (VOIs) placed on each patient's dominant tumor and benign prostate tissue. Metrics were compared between benign and malignant tissue, between Gleason score (GS) ≤ 3 + 3 and GS ≥ 3 + 4 tumors, and between GS ≤ 3 + 4 and GS ≥ 4 + 3 tumors by using paired t tests, analysis of variance, receiver operating characteristic (ROC) analysis, and exact tests. Results ADC and K showed significant differences for benign versus tumor tissues, GS ≤ 3 + 3 versus GS ≥ 3 + 4 tumors, and GS ≤ 3 + 4 versus GS ≥ 4 + 3 tumors (P < .001 for all). ADC and K were highly correlated (r = -0.82; P < .001). Area under the ROC curve was significantly higher (P = .002) for ADC (0.921) than for K (0.902) for benign versus malignant tissue but was similar for GS ≤ 3 + 3 versus GS ≥ 3 + 4 tumors (0.715-0.744) and GS ≤ 3 + 4 versus GS ≥ 4 + 3 tumors (0.694-0.720) (P > .15). ADC and K were concordant for these various outcomes in 80.0%-88.6% of patients; among patients with discordant results, ADC showed better performance than K for GS ≤ 3 + 4 versus GS ≥ 4 + 3 tumors (P = .016) and was similar to K for other outcomes (P > .136). Conclusion ADC and K were highly correlated, had similar diagnostic performance, and were concordant for the various outcomes in the large majority of cases. These observations did not show a clear added value of DK imaging compared with standard DW imaging for clinical PC evaluation. © RSNA, 2017 Online supplemental material is available for this article.
引用
- Tamada T, Prabhu V, Li J, et al. Prostate Cancer: Diffusion-weighted MR Imaging for Detection and Assessment of Aggressiveness-Comparison between Conventional and Kurtosis Models. Radiology. 2017. PMID: 28394755. doi:10.1148/radiol.2017162321
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。