文献速递泌尿生殖腹部MR

采用影像衍生、3D打印、患者特异性全前列腺包埋模具改善前列腺磁共振成像与病理对照

Improved Magnetic Resonance Imaging-Pathology Correlation With Imaging-Derived, 3D-Printed, Patient-Specific Whole-Mount Molds of the Prostate.
PubMed 文献 · Invest Radiol · 2017-01-01

该研究前瞻性纳入50例接受3 T多参数前列腺MRI后行根治性前列腺切除术的男性,比较基于MRI定制的3D打印模具(PSM)与传统全包埋切片(WMS)在MRI与病理解剖配准上的差异。结果显示,PSM组在前列腺整体、肿瘤、外周带和移行带的Dice相似系数均显著优于传统WMS组(P < 0.0001)。结论认为,PSM用于前列腺标本全包埋切片可提供显著更优的体内MRI与离体全包埋标本解剖配准。

要点

  • PSM组前列腺整体Dice相似系数(R1 0.95、R2 0.93)高于传统WMS组(均为0.85),P < 0.0001。
  • PSM组肿瘤Dice相似系数(R1 0.86、R2 0.75)高于传统WMS组(均为0.46),P < 0.0001。
  • PSM组外周带与移行带Dice相似系数亦显著高于传统WMS组(P < 0.0001)。

核心结论

  • 使用PSM进行前列腺标本全包埋切片,可使体内多参数MRI与离体前列腺全包埋标本的解剖配准显著优于传统WMS。

研究设计与样本

  • 前瞻性研究,根据先验效能分析纳入50例连续接受3 T多参数前列腺MRI后行根治性前列腺切除术的男性;研究组(n = 25)采用PSM全包埋切片,对照组(n = 25)采用传统WMS;以全包埋组织病理学感兴趣区为参考标准,由两名盲法独立阅片者(R1和R2)在MRI上勾画前列腺、肿瘤、外周带和移行带轮廓,计算Dice相似系数,采用Wilcoxon秩和检验比较两组。

诊断标准与关键数值

  • 以全包埋组织病理学感兴趣区为参考标准;PSM组Dice相似系数:R1前列腺0.95、肿瘤0.86、外周带0.84、移行带0.89,R2前列腺0.93、肿瘤0.75、外周带0.78、移行带0.85;传统WMS组Dice相似系数:R1和R2均为前列腺0.85、肿瘤0.46、外周带0.66、移行带0.69;两组比较P < 0.0001。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to compare the anatomical registration of preoperative magnetic resonance imaging (MRI) and prostate whole-mount obtained with 3D-printed, patient-specific, MRI-derived molds (PSM) versus conventional whole-mount sectioning (WMS).

MATERIALS AND METHODS: Based on an a priori power analysis, this institutional review board-approved study prospectively included 50 consecutive men who underwent 3 T multiparametric prostate MRI followed by radical prostatectomy. Two blinded and independent readers (R1 and R2) outlined the contours of the prostate, tumor, peripheral, and transition zones in the MRI scans using regions of interest. These were compared with the corresponding regions of interest from the whole-mounted histopathology, the reference standard, using PSM whole-mount results obtained in the study group (n = 25) or conventional WMS in the control group (n = 25). The spatial overlap across the MRI and histology data sets was calculated using the Dice similarity coefficient (DSC) for the prostate overall (DSCprostate), tumor (DSCtumor), peripheral (DSCPZ), and transition (DSCTZ) zone. Results in the study and control groups were compared using Wilcoxon rank sum test.

RESULTS: The MRI histopathology anatomical registration for the prostate gland overall, tumor, peripheral, and transition zones were significantly superior with the use of PSMs (DSCs for R1: 0.95, 0.86, 0.84, and 0.89; for R2: 0.93, 0.75, 0.78, and 0.85, respectively) than with the use of standard WMS (R1: 0.85, 0.46, 0.66, and 0.69; R2: 0.85, 0.46, 0.66, and 0.69) (P < 0.0001).

CONCLUSIONS: The use of PSMs for prostate specimen whole-mount sectioning provides significantly superior anatomical registration of in vivo multiparametric MRI and ex vivo prostate whole-mounts than conventional WMS.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Costa DN, Chatzinoff Y, Passoni NM, et al. Improved Magnetic Resonance Imaging-Pathology Correlation With Imaging-Derived, 3D-Printed, Patient-Specific Whole-Mount Molds of the Prostate. Invest Radiol. 2017. PMID: 28379863. doi:10.1097/RLI.0000000000000372

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。