自动部分肢体体积测量提高晚孕期胎儿出生体重预测的精确度

Automated Fractional Limb Volume Measurements Improve the Precision of Birth Weight Predictions in Late Third-Trimester Fetuses.
PubMed 文献 · J Ultrasound Med · 2017-04-25

研究前瞻性纳入50例孕妇在分娩前4天内进行二维和三维胎儿生物测量,比较Hadlock模型与Lee模型(含自动部分肢体体积)预测出生体重的表现。Hadlock模型准确度最高(系统误差0.31%),但自动部分臂体积(-9.1%±5.1%)和部分大腿体积(-5.2%±5.2%)模型精确度最优,校正系统误差后可改善预测误差的大小与分布。

要点

  • 自动部分肢体体积模型预测出生体重精确度优于Hadlock模型(随机误差±5.1%~±5.2% vs ±7.9%)。
  • 部分臂体积和部分大腿体积模型存在系统性低估(-9.1%和-5.2%),校正后可改善误差分布。
  • Hadlock模型准确度最高(系统误差0.31%),但随机误差较大(±7.9%)。

核心结论

  • 自动部分肢体体积测量可提高晚孕期胎儿体重预测的精确度;使用基于手动描记胎儿肢体软组织边界的预测模型时,可能需要校正因子来调整低估的系统误差。

研究设计与样本

  • 前瞻性研究,50例孕妇在分娩前4天内进行二维和三维胎儿生物测量,比较Hadlock模型(双顶径、腹围、股骨干长度)与Lee模型(双顶径、腹围、自动部分肢体体积)的出生体重预测表现。

诊断标准与关键数值

  • 系统误差(准确度)以百分差的符号均值表示,随机误差(精确度)以百分差的±1 SD表示;Hadlock模型系统误差0.31%、随机误差±7.9%;部分臂体积模型系统误差-9.1%、随机误差±5.1%;部分大腿体积模型系统误差-5.2%、随机误差±5.2%。

临床应用与阅片要点

  • 原文结论提示自动部分肢体体积测量可提高晚孕期胎儿体重预测精确度,但作者指出使用基于手动描记胎儿肢体软组织边界的预测模型时,可能需要校正因子调整低估的系统误差。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Fetal soft tissue can be assessed by using fractional limb volume as a proxy for in utero nutritional status. We investigated automated fractional limb volume for rapid estimate fetal weight assessment.

METHODS: Pregnant women were prospectively scanned for 2- and 3-dimensional fetal biometric measurements within 4 days of delivery. Performance of birth weight prediction models was compared: (1) Hadlock (Am J Obstet Gynecol 1985; 151:333-337; biparietal diameter, abdominal circumference, and femur diaphysis length); and (2) Lee (Ultrasound Obstet Gynecol 2009; 34:556-565; biparietal diameter, abdominal circumference, and automated fractional limb volume). Percent differences were calculated: [(estimated birth weight - actual birth weight) ÷ (actual birth weight] × 100. Systematic errors (accuracy) were summarized as signed mean percent differences. Random errors (precision) were calculated as ± 1 SD of percent differences.

RESULTS: Fifty neonates were delivered at 39.4 weeks' gestation. The Hadlock model generated the most accurate birth weight (0.31%) with a mean random error of ±7.9%. Despite systematic underestimations, the most precise results occurred with fractional arm volume (-9.1% ± 5.1%) and fractional thigh (-5.2% ± 5.2%) models. The size and distribution of these prediction errors were improved after correction for systematic errors.

CONCLUSIONS: Automated fractional limb volume measurements can improve the precision of weight predictions in third-trimester fetuses. Correction factors may be necessary to adjust underestimated systematic errors when using automated fractional limb volume with prediction models that are based on manual tracing of fetal limb soft tissue borders.

来源:J Ultrasound Med,查看原文。版权归原作者所有。