比较Gd-EOB-DTPA增强MRI T1 mapping中10分钟与20分钟肝胆期图像用于临床肝功能评估

Comparison of 10- and 20-min hepatobiliary phase images on Gd-EOB-DTPA-enhanced MRI T1 mapping for liver function assessment in clinic.
PubMed 文献 · Abdom Radiol (NY) · 2017-01-01

研究纳入103例患者分为肝功能正常组、肝硬化Child-Pugh A、B、C组,比较Gd-EOB-DTPA增强后10分钟与20分钟肝胆期T1 mapping的T1弛豫时间及下降率,发现两组时间点间无显著差异,10分钟肝胆期T1 mapping是定量评估肝功能的可行选择。

要点

  • 10分钟与20分钟肝胆期T1弛豫时间及下降率在各组间均无显著差异。
  • 肝功能正常组与肝硬化Child-Pugh A组间T1弛豫时间无显著差异。
  • 10分钟与20分钟肝胆期鉴别正常与Child-Pugh A组AUC仅0.532~0.582,诊断效能较低。

核心结论

  • 比较Gd-EOB-DTPA增强后10分钟与20分钟肝胆期T1 mapping,结果提示10分钟肝胆期T1 mapping是定量评估肝功能的可行选择。

研究设计与样本

  • 3.0 T MRI上比较Gd-EOB-DTPA增强后10分钟与20分钟肝胆期图像的前瞻性对照研究,共103例患者,分为肝功能正常组38例、肝硬化Child-Pugh A组33例、Child-Pugh B组21例、Child-Pugh C组11例,在T1 mapping上测量T1弛豫时间并计算下降率。

关键影像表现/征象

  • 增强前T1弛豫时间在四组间无显著差异(p > 0.05)。
  • 10分钟与20分钟肝胆期T1弛豫时间在各组间均有显著差异(p < 0.05),但肝功能正常组与Child-Pugh A组间无显著差异(p > 0.05)。
  • 10分钟与20分钟肝胆期T1弛豫时间及下降率在各组间均无显著差异(p > 0.05)。

诊断标准与关键数值

  • 10分钟与20分钟肝胆期鉴别肝功能正常组与Child-Pugh A组的AUC分别为0.532至0.582,诊断效能较低。
  • 10分钟与20分钟肝胆期在其他组间比较的AUC为0.788至1.000,诊断效能较高。

临床应用与阅片要点

  • 10分钟肝胆期T1 mapping可作为定量评估肝功能的可行选择。
  • 鉴别肝功能正常与Child-Pugh A级肝硬化时,10分钟与20分钟肝胆期T1 mapping诊断效能均较低(AUC 0.532~0.582)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare hepatobiliary phase (HBP) images obtained 10 and 20 min after Gd-EOB-DTPA-enhanced MRI for liver function assessment in clinic on 3.0 T MR imaging.

METHODS: 103 patients were separated into four groups: 38 patients for the normal liver function (NLF) group, 33 patients for the liver cirrhosis with Child-Pugh A (LCA) group, 21 patients for the liver cirrhosis with Child-Pugh B group, and 11 patients for a liver cirrhosis with Child-Pugh C group. T1 relaxation times (T1rt) were measured on T1 mapping and reduction rates of T1rt (rrT1rt) were calculated. HBP images were obtained at the 10- and 20-min mark after Gd-EOB-DTPA enhancement.

RESULTS: T1rt on pre-enhancement imaging showed no significant difference (p > 0.05) among all four groups. T1rt for both the 10-min HBP and the 20-min HBP showed a significant difference (p < 0.05) among all groups, but showed no significant difference (p > 0.05) between the NLF group and the LCA group. T1rt and rrT1rt showed no significant difference (p > 0.05) between 10-min HBP and 20-min HBP among all groups. The ROC analysis on 10-min HBP and 20-min HBP showed a lower diagnostic performance between NLF group and LCA group (AUC from 0.532 to 0.582), but high diagnostic performance (AUC from 0.788 to 1.000) among others group.

CONCLUSIONS: In comparing 10-min HBP and 20-min HBP T1 mapping after Gd-EOB-DTPA enhancement, our results suggest that 10-min HBP T1 mapping is a feasible option for quantitatively assessing liver function.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。