钆塞酸增强T1加权磁共振胆管成像对移植后胆道并发症诊断的附加价值
本研究分析60例疑似胆道并发症的肝移植患者,比较T2w-MRCP与联合T1w-MRC对吻合口狭窄、非吻合口狭窄和胆管的诊断效能,参考标准为ERCP或PTC。联合序列较单用T2w-MRCP提高敏感度和特异度,T1w-MRC在75-83.3%的病例中被认为有帮助。
要点
- 联合T1w-MRC与T2w-MRCP可提高移植后胆道并发症诊断的敏感度和特异度。
- T1w-MRC在75-83.3%的病例中被认为对诊断有帮助。
- 所有序列图像质量高且无显著差异。
核心结论
- 联合T1w-MRC与T2w-MRCP提高了肝移植后疑似胆道并发症患者的诊断敏感度、特异度和诊断信心;T1w-MRC是评估移植后胆道并发症的有价值工具。
研究设计与样本
- 研究纳入60例疑似胆道并发症的肝移植患者,行T2w-MRCP和T1w-MRC,随后行ERCP或PTC作为参考标准;两名阅片者独立评估图像质量和吻合口狭窄、非吻合口狭窄、胆管的可能性,计算敏感度、特异度、预测值,行ROC曲线分析并评估阅片者间一致性。
诊断标准与关键数值
- 吻合口狭窄:T2w-MRCP的敏感度和特异度分别为64-96,联合所有序列后分别提高至79-100。
- 非吻合口狭窄:T2w-MRCP的敏感度为72-92%,联合所有序列后提高至88-100%。
- 胆管:T2w-MRCP的敏感度为67-89%,联合所有序列后提高至72-94%。
- 阅片者间一致性Kappa值为0.45-0.62,为中等至高度一致。
- 图像质量评分在2.83-2.88之间,所有序列间无显著差异。
临床应用与阅片要点
- 在肝移植后疑似胆道并发症患者中,联合T1w-MRC与T2w-MRCP可提高诊断信心和诊断效能。
- T1w-MRC在75-83.3%的病例中被阅片者认为有帮助。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Biliary complications after liver transplantation (LT) are common. This study aimed to ascertain the value of gadoxetic acid-enhanced T1-weighted (T1w) magnetic resonance cholangiography (MRC) to evaluate anastomotic strictures (AS), non-anastomotic strictures (NAS) and biliary casts (BC).
METHODS: Sixty liver-transplanted patients with suspicion of biliary complications and T2w-MRCP and T1w-MRC followed by endoscopic retrograde cholangiopancreatography (ERCP) or percutaneous transhepatic cholangiography (PTC) were analysed. Two readers reviewed the MRCs and rated image quality (IQ) and likelihood for AS/NAS/BC on Likert scales. Sensitivity, specificity and predictive values were calculated, ROC curve analysis performed, and inter-reader variability assessed. The subjective added value of T1w-MRC was rated.
RESULTS: IQ was high for all sequences without significant differences (2.83-2.88). In 39 patients ERCP/PTC detected a complication. Sensitivity and specificity for AS were 64-96 using T2w-MRCP, increasing to 79-100 using all sequences. Use of all sequences increased the sensitivity of detecting NAS/BC from 72-92% to 88-100% and 67-89% to 72-94%, respectively. Kappa values were substantial (0.45-0.62). T1w-MRC was found to be helpful in 75-83.3%.
CONCLUSIONS: Combining T1w-MRC and T2w-MRCP increased sensitivity and specificity and diagnostic confidence in patients after LT with suspected biliary complications. T1w-MRC is a valuable tool for evaluating post-transplant biliary complications.
KEY POINTS: • T1w-MRC is a valuable tool for evaluating post-transplant biliary complications. • Adding T1w-MRC to T2w-MRC increases diagnostic confidence for detection of biliary complications. • A combination of T1w-MRC and T2w-MRCP leads to the best results.
引用
- Kinner S, Schubert TB, Said A, et al. Added value of gadoxetic acid-enhanced T1-weighted magnetic resonance cholangiography for the diagnosis of post-transplant biliary complications. Eur Radiol. 2017. PMID: 28409358. doi:10.1007/s00330-017-4797-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。