文献速递腹部MR

高速T1序列用于高质量肝脏动脉期磁共振成像:单动脉期与多动脉期的个体内比较

Application of High-Speed T1 Sequences for High-Quality Hepatic Arterial Phase Magnetic Resonance Imaging: Intraindividual Comparison of Single and Multiple Arterial Phases.
PubMed 文献 · Invest Radiol · 2017-01-01

回顾性纳入67例接受钆塞酸增强肝脏MRI并完成单、双、三动脉期采集的患者,比较动脉期时机合适性与呼吸运动伪影。单动脉期时机合适率为89.6%(60/67),双及三动脉期均为98.5%(66/67)(P=0.015);呼吸运动伪影评分单动脉期1.70、双动脉期1.90、三动脉期2.49(P<0.001),单与双动脉期之间无显著差异(P=0.091)。结论认为15秒屏气双动脉期可可靠提供时机良好且呼吸运动伪影较少的肝动脉期,而13秒屏气单动脉期在减少呼吸运动伪影方面最有效。

要点

  • 双动脉期与三动脉期动脉期时机合适率均为98.5%(66/67),高于单动脉期的89.6%(60/67)(P=0.015)。
  • 呼吸运动伪影评分单动脉期1.70、双动脉期1.90、三动脉期2.49(P<0.001),单与双动脉期无显著差异(P=0.091)。
  • 15秒屏气双动脉期可可靠获得时机良好的肝动脉期且呼吸运动伪影较少,13秒屏气单动脉期减少呼吸运动伪影最有效。

核心结论

  • 钆塞酸增强MRI中15秒屏气双动脉期采集可可靠提供时机良好的肝动脉期并减少呼吸运动伪影,而13秒屏气单动脉期在减少呼吸运动伪影方面最有效。

研究设计与样本

  • 回顾性纳入67例接受钆塞酸增强肝脏MRI并完成单、双、三动脉期全部3种采集的患者,肝动脉期成像采用CAIPIRINHA伴或不伴TWIST。

关键影像表现/征象

  • 肝动脉期时机合适率单动脉期为89.6%(60/67),双动脉期和三动脉期均为98.5%(66/67)(P=0.015)。
  • 呼吸运动伪影采用5分制评分(分值越高图像质量越差),单动脉期平均1.70、双动脉期1.90、三动脉期2.49(P<0.001)。
  • 单动脉期与双动脉期呼吸运动伪影评分无显著差异(P=0.091)。

诊断标准与关键数值

  • 肝动脉期时机合适性以是否达到最佳肝动脉时机评估,单动脉期89.6%(60/67)、双动脉期98.5%(66/67)、三动脉期98.5%(66/67)(P=0.015)。
  • 呼吸运动伪影采用5分制评分,最高分表示图像质量最差,单动脉期1.70、双动脉期1.90、三动脉期2.49(P<0.001)。

临床应用与阅片要点

  • 15秒屏气双动脉期采集可可靠获得时机良好的肝动脉期且呼吸运动伪影较少。
  • 13秒屏气单动脉期采集在减少呼吸运动伪影方面最有效。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of this study was to compare intraindividual single and multiple arterial phase acquisitions and evaluate which acquisition method was more advantageous for obtaining high-quality hepatic arterial phase in gadoxetic acid-enhanced liver magnetic resonance imaging (MRI).

MATERIALS AND METHODS: Sixty-seven patients who underwent gadoxetic acid-enhanced liver MRIs and had all 3 kinds of acquisitions (single, dual, and triple arterial phases) were retrospectively included. For hepatic arterial phase imaging, controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) with or without time-resolved imaging with interleaved stochastic trajectories (TWIST) was used. The adequacy of optimal hepatic arterial timing was assessed and respiratory motion artifacts were rated using a 5-point scale, with the highest score indicating the worst image quality. Optimal timing and respiratory motion artifacts among 3 different acquisitions were compared using Fisher exact test and repeated measures one-way analysis of variance with multiple comparisons.

RESULTS: Optimal timing of hepatic arterial phase was observed in 89.6% (60/67) of single arterial phase acquisitions and 98.5% (66/67) of both dual and triple arterial phase acquisitions (P = 0.015). Respiratory motion artifact was significantly lower in single and dual arterial acquisitions than in triple arterial acquisition (mean score, 1.70 vs 1.90 vs 2.49; P < 0.001), although there was no significant difference between single and dual arterial acquisitions (P = 0.091).

CONCLUSIONS: A 15-second breath-hold dual arterial phase acquisition during gadoxetic acid-enhanced MRI reliably offers well-timed hepatic arterial phase with less respiratory motion artifact. However, a 13-second breath-hold single arterial phase acquisition was most effective in reducing respiratory motion artifact.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Park YS, Lee CH, Kim JW, et al. Application of High-Speed T1 Sequences for High-Quality Hepatic Arterial Phase Magnetic Resonance Imaging: Intraindividual Comparison of Single and Multiple Arterial Phases. Invest Radiol. 2017. PMID: 28441159. doi:10.1097/RLI.0000000000000378

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。