声辐射力脉冲成像术前评估胆道闭锁婴儿肝纤维化:与肝纤维化活检病理对照
本研究纳入50例胆道闭锁婴儿和50例健康婴儿行声辐射力脉冲成像测量剪切波速度,胆道闭锁婴儿在成像后3天内行肝活检并按Batts-Ludwig评分系统分期。胆道闭锁组平均剪切波速度显著高于对照组(1.89±0.45 vs 1.12±0.06 m/s,P<.001),剪切波速度与纤维化分期显著相关(r=0.719,P<.001),预测F≥2、F≥3和F=4的cut-off值分别为1.53、1.80和2.16 m/s,AUC分别为0.823、0.884和0.917。作者认为声辐射力脉冲成像可能是一种有效的肝纤维化评估方法。
要点
- 胆道闭锁组平均剪切波速度1.89±0.45 m/s,显著高于健康对照组1.12±0.06 m/s(P<.001)。
- 剪切波速度与肝纤维化分期显著相关(r=0.719,P<.001)。
- 预测F≥2、F≥3、F=4的cut-off值分别为1.53、1.80、2.16 m/s,AUC分别为0.823、0.884、0.917。
核心结论
- 声辐射力脉冲成像与肝纤维化活检病理所示的纤维化严重程度显著相关(r=0.719,P<.001)。
- 作者认为声辐射力脉冲成像可能是胆道闭锁婴儿肝纤维化评估、预后预测和临床管理的有效方法。
研究设计与样本
- 本研究为诊断性研究,纳入50例连续胆道闭锁婴儿和50例健康婴儿,均行声辐射力脉冲成像检查。
- 使用Siemens Acuson S2000的Virtual Touch Quantification模式测量剪切波速度。
- 所有胆道闭锁婴儿在声辐射力脉冲成像后3天内行肝活检,标本按Batts-Ludwig评分系统定义肝纤维化分期。
- 以肝活检病理为参考标准,分析剪切波速度与病理表现的相关性,并用受试者工作特征曲线确定cut-off值。
诊断标准与关键数值
- 胆道闭锁组平均剪切波速度为1.89±0.45 m/s,健康对照组为1.12±0.06 m/s,组间差异有统计学意义(P<.001)。
- 剪切波速度与肝纤维化分期的相关系数r=0.719(P<.001)。
- 预测显著纤维化(F≥2)的cut-off值为1.53 m/s,AUC为0.823。
- 预测严重纤维化(F≥3)的cut-off值为1.80 m/s,AUC为0.884。
- 预测肝硬化(F=4)的cut-off值为2.16 m/s,AUC为0.917。
临床应用与阅片要点
- 作者认为声辐射力脉冲成像可能是胆道闭锁婴儿肝纤维化评估、预后预测和临床管理的有效方法。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The purpose of this study was to investigate the diagnostic performance of acoustic radiation force impulse (ARFI) in assessing liver fibrosis preoperatively in infants with biliary atresia (BA).
METHODS: A total of 50 consecutive infants with BA and 50 healthy infants who underwent ARFI examination were recruited. Siemens Acuson S2000 in Virtual Touch Quantification mode (Siemens Medical Solutions, Mountain View, CA) was used to measure shear wave speeds (SWSs). All infants with BA underwent a liver biopsy within 3 days after ARFI imaging. The liver fibrosis stages of specimens were defined according to the Batts-Ludwig scoring system. The correlation analysis was performed between SWSs and pathological findings. Cut-off values were determined using receiver operating characteristic (ROC) curves.
RESULTS: The mean SWS in the BA group was significantly higher than controls (mean ± standard deviation): 1.89 ± 0.45 versus 1.12 ± 0.06 m/s; P < .001). A significant correlation was found between the SWSs and fibrosis stages (r = 0.719, P < .001). The cut-off value for predicting significant fibrosis (F ≥ 2), severe fibrosis (F ≥ 3), and cirrhosis (F = 4) was 1.53, 1.80 and 2.16 m/s, respectively, and the area under the ROC curve was 0.823, 0.884 and 0.917, respectively.
CONCLUSIONS: Acoustic radiation force impulse imaging showed significant correlation with the severity of liver fibrosis by comparing it with liver fibrosis biopsy pathology. It may be an effective method for liver fibrosis assessment, prognosis prediction, and clinical management in infants with BA.
引用
- Gao F, Chen YQ, Fang J, et al. Acoustic Radiation Force Impulse Imaging for Assessing Liver Fibrosis Preoperatively in Infants With Biliary Atresia: Comparison With Liver Fibrosis Biopsy Pathology. J Ultrasound Med. 2017. PMID: 28407283. doi:10.7863/ultra.16.08043