基于模型的迭代重建对腹部CT低对比度病灶检测及图像质量的影响:一项12名阅片者参与的与滤波反投影在不同管电压下的体模对比研究
研究在模拟中等和大体型患者的体模中,比较基于模型的迭代重建(MBIR)与滤波反投影(FBP)在70、80、100、120 kVp管电压下腹部CT的图像质量和低对比度病灶检出率。MBIR使图像噪声降低24%和27%,对比噪声比(CNR)提高30%和29%;低管电压使CNR提高,但12名放射科医生阅片显示病灶检出率无显著差异(中等体模79-82%,大体模57-65%,P>0.37)。
要点
- MBIR较FBP降低图像噪声并提高CNR,但未提高低对比度病灶检出率。
- 降低管电压提高CNR,但同样未改善病灶检出率。
- 图像噪声和CNR的变化不直接影响诊断准确性。
核心结论
- 尽管MBIR较FBP改善了定量图像质量,但在不同管电压下模拟中等和大体型患者的腹部CT中并未增加低对比度病灶的检出。
研究设计与样本
- 体模研究,使用含45个低密度病灶的体模置于两个水容器中,在70、80、100、120 kVp下扫描,120 kVp协议为参考,所有协议CTDIvol保持恒定;数据集分别用MBIR和FBP重建,由12名放射科医生评估低对比度病灶检出率。
关键影像表现/征象
- MBIR较FBP使中等体模图像噪声降低24%、大体模降低27%。
- MBIR较FBP使中等体模CNR提高30%、大体模提高29%。
- 与120 kVp相比,中等体模在70、80、100 kVp下CNR分别提高58%、46%、16%;大体模分别提高9%、18%、12%。
诊断标准与关键数值
- 低对比度病灶检出率:中等体模MBIR与FBP为79-82%,大体模为57-65%,差异无统计学意义(P>0.37)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the impact of model-based iterative reconstruction (MBIR) on image quality and low-contrast lesion detection compared with filtered back projection (FBP) in abdominal computed tomography (CT) of simulated medium and large patients at different tube voltages.
METHODS: A phantom with 45 hypoattenuating lesions was placed in two water containers and scanned at 70, 80, 100, and 120 kVp. The 120-kVp protocol served as reference, and the volume CT dose index (CTDIvol) was kept constant for all protocols. The datasets were reconstructed with MBIR and FBP. Image noise and contrast-to-noise-ratio (CNR) were assessed. Low-contrast lesion detectability was evaluated by 12 radiologists.
RESULTS: MBIR decreased the image noise by 24% and 27%, and increased the CNR by 30% and 29% for the medium and large phantoms, respectively. Lower tube voltages increased the CNR by 58%, 46%, and 16% at 70, 80, and 100 kVp, respectively, compared with 120 kVp in the medium phantom and by 9%, 18% and 12% in the large phantom. No significant difference in lesion detection rate was observed (medium: 79-82%; large: 57-65%; P > 0.37).
CONCLUSIONS: Although MBIR improved quantitative image quality compared with FBP, it did not result in increased low-contrast lesion detection in abdominal CT at different tube voltages in simulated medium and large patients.
KEY POINTS: • MBIR improved quantitative image quality but not lesion detection compared with FBP. • Increased CNR by low tube voltages did not improve lesion detection. • Changes in image noise and CNR do not directly influence diagnostic accuracy.
引用
- Euler A, Stieltjes B, Szucs-Farkas Z, et al. Impact of model-based iterative reconstruction on low-contrast lesion detection and image quality in abdominal CT: a 12-reader-based comparative phantom study with filtered back projection at different tube voltages. Eur Radiol. 2017. PMID: 28374080. doi:10.1007/s00330-017-4825-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。