低剂量CT中迭代重建算法:哪种类型能确保年轻肿瘤患者的诊断图像质量?

Iterative Reconstructions in Reduced-Dose CT: Which Type Ensures Diagnostic Image Quality in Young Oncology Patients?
PubMed 文献 · Acad Radiol · 2017-03-29

纳入44例年轻肿瘤患者(平均年龄30±9岁),在常规胸腹部CT后行50%剂量随访CT(29例另加20%剂量),分别用ASIR和MBIR重建。MBIR在各级剂量下客观噪声显著低于ASIR(P<0.001),低对比结构主观图像质量显著更高(P<0.001),且诊断信心更高;高BMI患者低剂量腹部CT诊断信心反而更高(P<0.001)。作者结论:年轻肿瘤患者随访低剂量CT应采用MBIR重建以确保诊断质量。

要点

  • 低剂量随访CT中MBIR客观噪声显著低于ASIR(P<0.001),低对比结构主观质量更高(P<0.001)。
  • MBIR图像像素化外观更明显,但诊断信心更高,尤其对低年资医师(P<0.001)。
  • 高BMI患者低剂量腹部CT诊断信心和主观图像质量反而更高(P<0.001),与重建技术无关。

核心结论

  • 年轻肿瘤患者随访低剂量CT应采用MBIR重建以确保诊断质量,高BMI并不妨碍低剂量CT质量。

研究设计与样本

  • 前瞻性自身对照研究,纳入44例年轻肿瘤患者(平均年龄30±9岁),先行常规胸腹部CT(100%剂量,平均CTDIvol 9.1±2.4 mGy,范围4.4-16.9 mGy),随访CT在50%剂量(平均CTDIvol 4.5±1.2 mGy,范围2.2-8.4 mGy)采集,其中29例另在20%剂量(平均CTDIvol 1.9±0.5 mGy,范围0.9-3.4 mGy)采集;每次低剂量CT均分别用ASIR和MBIR重建,由4名放射科医师(2名低年资、2名高年资)在不知剂量和技术条件下评估。

诊断标准与关键数值

  • 在所有剂量水平,MBIR的客观图像噪声均显著低于ASIR(P<0.001);低对比结构的主观图像质量MBIR显著高于ASIR(P<0.001);MBIR图像像素化外观显著多于ASIR,但诊断信心更高,尤其低年资医师(P<0.001);高BMI患者低剂量腹部CT的诊断信心显著高于较瘦患者(P<0.001),主观图像质量也更高,与重建技术无关。

临床应用与阅片要点

  • 作者结论认为年轻肿瘤患者随访低剂量CT应采用MBIR重建以确保诊断质量,高BMI不妨碍低剂量CT质量。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To compare adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) algorithms for reduced-dose computed tomography (CT).

MATERIALS AND METHODS: Forty-four young oncology patients (mean age 30 ± 9 years) were included. After routine thoraco-abdominal CT (dose 100%, average CTDIvol 9.1 ± 2.4 mGy, range 4.4-16.9 mGy), follow-up CT was acquired at 50% (average CTDIvol 4.5 ± 1.2 mGy, range 2.2-8.4 mGy) in 29 patients additionally at 20% dose (average CTDIvol 1.9 ± 0.5 mGy, range 0.9-3.4 mGy). Each reduced-dose CT was reconstructed using both ASIR and MBIR. Four radiologists (two juniors and two seniors) blinded to dose and technique read each set of CT images regarding objective and subjective image qualities (high- or low-contrast structures), subjective noise or pixilated appearance, diagnostic confidence, and lesion detection.

RESULTS: At all dose levels, objective image noise was significantly lower with MBIR than with ASIR (P < 0.001). The subjective image quality for low-contrast structures was significantly higher with MBIR than with ASIR (P < 0.001). Reduced-dose abdominal CT images of patients with higher body mass index (BMI) were read with significantly higher diagnostic confidence than images of slimmer patients (P < 0.001) and had higher subjective image quality, regardless of technique. Although MBIR images appeared significantly more pixilated than ASIR images, they were read with higher diagnostic confidence, especially by juniors (P < 0.001).

CONCLUSIONS: Reduced-dose CT during the follow-up of young oncology patients should be reconstructed with MBIR to ensure diagnostic quality. Elevated body mass index does not hamper the quality of reduced-dose CT.

来源:Acad Radiol,查看原文。版权归原作者所有。