文献速递介入腹部胸部CT

弯曲经皮引流导管以便利用弯曲套管针技术行CT引导置入

Bending percutaneous drainage catheters to facilitate CT-guided insertion using curved trocar technique.
PubMed 文献 · Abdom Radiol (NY) · 2017-01-01

回顾性研究纳入182例CT/CT透视引导下的胸腹部导管引流,比较弯曲导管套管针技术、直导管套管针技术与Seldinger技术。弯曲套管针技术操作时间28±8分钟,短于Seldinger技术的37±11分钟(p=.00002);CTDIvol为107.8±54.2 mGy,低于Seldinger技术的136.1±99.7 mGy(p=0.032);不良事件率三组间无显著差异(p=1)。作者认为弯曲导管套管针技术是标准套管针技术的一种安全有效的改良,可能有助于克服CT机架尺寸限制。

要点

  • 弯曲套管针技术操作时间28±8分钟,短于Seldinger技术的37±11分钟(p=.00002)。
  • 弯曲套管针技术CTDIvol为107.8±54.2 mGy,低于Seldinger技术的136.1±99.7 mGy(p=0.032)。
  • 弯曲套管针、直套管针与Seldinger技术不良事件率分别为2.3%(1/44)、0%(0/16)、3.3%(4/122),组间无显著差异(p=1)。

核心结论

  • 弯曲导管套管针技术是标准套管针技术的一种安全有效的改良,可能有助于克服CT机架尺寸限制所妨碍的CT引导操作。

研究设计与样本

  • 回顾性研究,共182例CT/CT透视引导下胸腹部导管引流;一半由住院医师或专科培训医师在一位放射科医师监督下完成(第1组),另一半由其他10位放射科医师监督下完成(第2组)。

诊断标准与关键数值

  • 第1组弯曲套管针技术(n=44)操作时间28±8分钟,短于第1组和第2组Seldinger技术(37±11分钟,p=.00002)。
  • 第1组弯曲套管针技术(n=44)CTDIvol为107.8±54.2 mGy,低于第1组和第2组Seldinger技术(136.1±99.7 mGy,p=0.032)。
  • 弯曲套管针、直套管针与Seldinger技术的不良事件率分别为2.3%(1/44)、0%(0/16)、3.3%(4/122),组间比较p=1;所有不良事件均为1级或2级,无导管故障发生。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the safety and efficacy of placing thoraco-abdominal drainage catheters under CT-guidance using a curved trocar technique.

METHODS: A retrospective study of 182 CT/CT-fluoroscopy-guided thoraco-abdominal catheter drainages was conducted; half were performed by residents or fellows under the supervision of one radiologist (Group 1) and the other half under the supervision of 10 other radiologists (Group 2). Group 1 procedures employed a curved catheter assembly placed using trocar technique (n = 44) or straight catheters placed with Seldinger technique (n = 47). Group 2 procedures employed a straight catheter placed using trocar technique (n = 16) or straight catheters placed with Seldinger technique (n = 75). Technical success, procedure time, radiation dose (CT Dose Index CTDIvol), and adverse events (Common Terminology Criteria for Adverse Events, 4.0) were compared between techniques and groups using Student's t test, Fisher's exact test or Chi-square analysis.

RESULTS: All procedures in groups 1 and 2 were technically successful. Mean procedure time for Group 1 curved trocar technique (28 ± 8 min) was shorter than groups 1 and 2 Seldinger technique (37 ± 11 min, p = .00002). Mean CTDIvol for Group 1 curved trocar technique (107.8 ± 54.2 mGy) was lower than groups 1 and 2 Seldinger technique (136.1 ± 99.7 mGy, p = 0.032). Adverse event rates for curved trocar, straight trocar, and Seldinger techniques were 2.3% (1/44), 0% (0/16), and 3.3% (4/122), respectively (p = 1); all were grade 1 or 2, and no catheter malfunctions occurred.

CONCLUSIONS: The curved catheter trocar technique is a safe and effective modification of the standard trocar technique that may facilitate CT-guided procedures impeded by CT gantry size limitations.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Young AS, Shyn PB, Johnson OW, et al. Bending percutaneous drainage catheters to facilitate CT-guided insertion using curved trocar technique. Abdom Radiol (NY). 2017. PMID: 28361226. doi:10.1007/s00261-017-1108-5