文献速递妇产影像US

普遍性与选择性超声筛查大于胎龄儿及相关疾病比较

Universal vs selective ultrasonography to screen for large-for-gestational-age infants and associated morbidity.
PubMed 文献 · Ultrasound Obstet Gynecol · 2018-04-30

本研究基于前瞻性队列数据,比较选择性超声与普遍性超声筛查大于胎龄儿的诊断效能。普遍性超声(36周左右测量估计胎儿体重)筛查敏感度38%、特异度97%,高于选择性超声的27%和99%。普遍性超声联合腹围增长速度可识别不良新生儿结局风险增高的疑似大于胎龄儿。

要点

  • 普遍性超声筛查大于胎龄儿敏感度38%,高于选择性超声的27%。
  • 两种方法特异度均高:普遍性超声97%,选择性超声99%。
  • 腹围增长速度增快的疑似大于胎龄儿,任何新生儿疾病相对风险2.0,严重不良结局相对风险6.5。

核心结论

  • 普遍性超声胎儿生物测量筛查可提高大于胎龄儿检出率,联合腹围增长速度可识别不良新生儿结局风险增高的胎儿。

研究设计与样本

  • 前瞻性队列研究(妊娠结局预测研究),纳入3866例 eligible 初产妇,所有参与者于36周左右接受研究性超声测量估计胎儿体重(普遍性超声),临床指征超声(选择性超声)按常规临床实践进行,参考标准为出生体重>90百分位。

诊断标准与关键数值

  • 大于胎龄儿筛查阳性定义为≥34周时估计胎儿体重>90百分位;选择性超声敏感度27%、特异度99%,普遍性超声敏感度38%、特异度97%;普遍性超声下,腹围增长速度增快的大于胎龄儿任何新生儿疾病相对风险2.0(95%CI 1.1-3.6,P=0.04),严重不良新生儿结局相对风险6.5(95%CI 2.0-21.1,P=0.01),腹围增长速度正常者风险未增高;交互作用P值:任何新生儿疾病P=0.08,严重不良结局P=0.03。

临床应用与阅片要点

  • 第三孕期普遍性超声胎儿生物测量可提高大于胎龄儿检出率,结合腹围增长速度有助于识别不良新生儿结局风险增高的疑似大于胎龄儿。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare the diagnostic effectiveness of selective vs universal ultrasonography as a screening test for large-for-gestational-age (LGA) infants, and to determine whether previously described ultrasound markers of excessive fetal growth could identify suspected LGA fetuses that are at increased risk of adverse neonatal outcome.

METHODS: Data from the Pregnancy Outcome Prediction study, a prospective cohort study of nulliparous women with a viable singleton pregnancy at the time of the dating ultrasound scan, were analyzed. Women were selected for clinically indicated ultrasound assessment in the third trimester as per routine clinical care, and the results of these scans were reported ('selective ultrasonography'). In addition, all participants underwent research ultrasound scans, including estimated fetal weight (EFW) assessment, at around 36 weeks' gestation, in which both the women and their clinicians were blinded to the results ('universal ultrasonography'). Participants who attended the 36-week research scan and had a live birth at the Rosie Hospital were included in the study. Screen positive for LGA was defined as EFW > 90th percentile at ≥ 34 weeks.

RESULTS: The current analysis included 3866 eligible women, of whom 1354 (35%) had a clinically indicated ultrasound scan at or after 34 weeks' gestation. A total of 177 (4.6%) infants had a birth weight > 90th percentile. The sensitivity for detection of LGA infants was 27% for selective ultrasonography and 38% for universal ultrasonography. The specificity of both approaches was high (99% and 97%, respectively). Using universal ultrasonography, neonatal outcome differed (P for interaction) by abdominal circumference growth velocity (ACGV) for both any neonatal morbidity (P = 0.08) and severe adverse neonatal outcome (P = 0.03). LGA fetuses with increased ACGV had a relative risk of any neonatal morbidity of 2.0 (95% CI, 1.1-3.6; P = 0.04) and of severe adverse neonatal outcome of 6.5 (95% CI, 2.0-21.1; P = 0.01), whereas LGA fetuses with normal ACGV were not at increased risk.

CONCLUSIONS: Third-trimester screening of nulliparous women by universal ultrasound fetal biometry increases the detection rate of LGA infants and, combined with ACGV, identifies those at increased risk of adverse neonatal outcome. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Sovio U, Moraitis AA, Wong HS, et al. Universal vs selective ultrasonography to screen for large-for-gestational-age infants and associated morbidity. Ultrasound Obstet Gynecol. 2018. PMID: 28425156. doi:10.1002/uog.17491

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。