文献速递儿科影像腹部技术与安全US

剪切波弹性成像评估健康新生儿和婴儿的肝脏、肾脏和脾脏弹性

Evaluation of Liver, Kidney, and Spleen Elasticity in Healthy Newborns and Infants Using Shear Wave Elastography.
PubMed 文献 · J Ultrasound Med · 2017-04-18

本研究用剪切波弹性成像检测50例健康足月新生儿和婴儿(平均20.1天,范围1至70天)的肝脏、肾脏和脾脏弹性,获得正常参考值:肝1.70 m/s、右肾1.69 m/s、左肾1.70 m/s、脾2.03 m/s;年龄、性别、体重、身高和体质指数对肝脾剪切波速度无显著影响,双肾剪切波速度随年龄、体重、身高和体质指数增加而降低。作者认为剪切波弹性成像可用于测量新生儿和婴儿腹部器官弹性,正常参考值有助于区分健康与病理组织。

要点

  • 健康新生儿和婴儿肝脏平均剪切波速度为1.70 m/s(范围1.23-2.43 m/s)。
  • 右肾平均剪切波速度为1.69 m/s(范围0.8-2.40 m/s),左肾为1.70 m/s(范围0.9-2.49 m/s)。
  • 脾脏平均剪切波速度为2.03 m/s(范围1.28-2.48 m/s),高于肝脏和肾脏。

核心结论

  • 剪切波弹性成像可用于测量新生儿和婴儿肝脏、肾脏和脾脏弹性,所测正常参考值有助于区分健康与病理组织。

研究设计与样本

  • 研究共纳入50例健康足月新生儿和婴儿(19例女孩、31例男孩;平均年龄20.1天,范围1至70天),由一名经验丰富的儿科放射科医生使用剪切波弹性成像进行检查;所有受试者无肝脏、肾脏或脾脏疾病,也无其他可能继发影响这些器官的系统性疾病,且腹部超声检查均正常。

诊断标准与关键数值

  • 肝脏平均剪切波速度为1.70 m/s(范围1.23-2.43 m/s)。
  • 右肾平均剪切波速度为1.69 m/s(范围0.8-2.40 m/s)。
  • 左肾平均剪切波速度为1.70 m/s(范围0.9-2.49 m/s)。
  • 脾脏平均剪切波速度为2.03 m/s(范围1.28-2.48 m/s)。
  • 年龄、性别、体重、身高和体质指数对肝脏和脾脏剪切波速度值无显著影响;双肾剪切波速度值随年龄、体重、身高和体质指数增加而降低。

临床应用与阅片要点

  • 作者指出剪切波弹性成像可用于测量新生儿和婴儿肝脏、肾脏和脾脏弹性。
  • 作者报告了健康新生儿和婴儿的剪切波弹性成像正常参考值,认为这些标准值有助于区分健康与病理组织。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Elasticity measurements of tissues can be valuable in the diagnosis and management of various diseases. The aim of this study was to determine the elasticity values for normal liver, kidney, and spleen of healthy newborns and infants using shear wave elastography (SWE) imaging.

METHODS: A total of 50 healthy term newborns and infants (19 girls and 31 boys; mean age 20.1 days, range 1 to 70 days) were examined by an experienced pediatric radiologist using SWE. None of them had any liver, kidney or spleen disease, or any other systemic disease that could affect these organs secondarily. All newborns and infants had a normal abdominal ultrasound scan.

RESULTS: Age, sex, weight, height, and body mass index had no significant effects on shear wave velocity (SWV) values of liver and spleen. The SWV values of both kidneys decreased with age, weight, height, and body mass index. The mean SWV values were 1.70 m/s (range: 1.23-2.43 m/s) for the liver, 1.69 m/s (range: 0.8-2.40 m/s) for the right kidney, 1.70 m/s (range: 0.9-2.49 m/s) for the left kidney, and 2.03 m/s (range: 1.28-2.48 m/s) for the spleen.

CONCLUSIONS: Shear wave elastography can be used to measure liver, kidney, and spleen elasticity in newborns and infants. The standard values for abdominal organs allow differentiation of healthy versus pathological tissue. We measured the normal values of SWE in healthy newborns and infants as reference data.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Palabiyik FB, Inci E, Turkay R, et al. Evaluation of Liver, Kidney, and Spleen Elasticity in Healthy Newborns and Infants Using Shear Wave Elastography. J Ultrasound Med. 2017. PMID: 28417472. doi:10.1002/jum.14202

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。