超声计算流体力学作为二尖瓣反流定量技术的可行性:与二维及三维近端等速表面积法的比较

Feasibility of Ultrasound-Based Computational Fluid Dynamics as a Mitral Valve Regurgitation Quantification Technique: Comparison with 2-D and 3-D Proximal Isovelocity Surface Area-Based Methods.
PubMed 文献 · Ultrasound Med Biol · 2017-04-20

本研究利用超声计算流体力学(Ub-CFD)定量二尖瓣反流,并与二维和三维PISA方法比较。体外流动环路实验显示Ub-CFD和三维PISA精度高于二维PISA,Ub-CFD在所有测试条件下准确性一致,而二维和三维PISA准确性显著依赖混叠速度选择。两例临床病例中同样观察到PISA对混叠速度的依赖性,Ub-CFD表现出稳健的准确性和精确性,有潜力转化至临床实践。

要点

  • Ub-CFD在体外所有测试条件下准确性一致,精度高于二维PISA。
  • 二维和三维PISA的准确性显著依赖混叠速度的选择。
  • Ub-CFD有潜力转化至临床实践,但尚需进一步验证。

核心结论

  • Ub-CFD在体外和两例临床病例中表现出稳健的准确性和精确性,有潜力转化至临床实践。

研究设计与样本

  • 采用超声计算流体力学(Ub-CFD)、二维PISA和三维PISA三种方法,在体外流动环路(含简化平板圆孔和三维打印真实二尖瓣及反流孔)及两例临床病例中进行评估。

诊断标准与关键数值

  • 体外流动环路实验中,Ub-CFD和三维PISA的精度高于二维PISA。
  • Ub-CFD在所有测试条件下准确性一致,二维PISA总体准确性最低。
  • 体外研究提示二维和三维PISA的准确性显著依赖混叠速度的选择。
  • 两例临床病例中同样观察到PISA对混叠速度的依赖性。

临床应用与阅片要点

  • 作者认为Ub-CFD有潜力转化至临床实践。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Current Doppler echocardiography quantification of mitral regurgitation (MR) severity has shortcomings. Proximal isovelocity surface area (PISA)-based methods, for example, are unable to account for the fact that ultrasound Doppler can measure only one velocity component: toward or away from the transducer. In the present study, we used ultrasound-based computational fluid dynamics (Ub-CFD) to quantify mitral regurgitation and study its advantages and disadvantages compared with 2-D and 3-D PISA methods. For Ub-CFD, patient-specific mitral valve geometry and velocity data were obtained from clinical ultrasound followed by 3-D CFD simulations at an assumed flow rate. We then obtained the average ratio of the ultrasound Doppler velocities to CFD velocities in the flow convergence region, and scaled CFD flow rate with this ratio as the final measured flow rate. We evaluated Ub-CFD, 2-D PISA and 3-D PISA with an in vitro flow loop, which featured regurgitation flow through (i) a simplified flat plate with round orifice and (ii) a 3-D printed realistic mitral valve and regurgitation orifice. The Ub-CFD and 3-D PISA methods had higher precision than the 2-D PISA method. Ub-CFD had consistent accuracy under all conditions tested, whereas 2-D PISA had the lowest overall accuracy. In vitro investigations indicated that the accuracy of 2-D and 3-D PISA depended significantly on the choice of aliasing velocity. Evaluation of these techniques was also performed for two clinical cases, and the dependency of PISA on aliasing velocity was similarly observed. Ub-CFD was robustly accurate and precise and has promise for future translation to clinical practice.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Jamil M, Ahmad O, Poh KK, et al. Feasibility of Ultrasound-Based Computational Fluid Dynamics as a Mitral Valve Regurgitation Quantification Technique: Comparison with 2-D and 3-D Proximal Isovelocity Surface Area-Based Methods. Ultrasound Med Biol. 2017. PMID: 28434658. doi:10.1016/j.ultrasmedbio.2017.02.012