心脏淀粉样变性患者超声心动图参数化舒张充盈分析显示舒张功能减低

Cardiac Amyloidosis Shows Decreased Diastolic Function as Assessed by Echocardiographic Parameterized Diastolic Filling.
PubMed 文献 · Ultrasound Med Biol · 2017-04-19

本研究对13例心脏淀粉样变性患者与13例年龄性别匹配对照进行经二尖瓣血流脉冲波多普勒超声心动图检查,采用参数化舒张充盈(PDF)分析。结果显示患者左房面积、室间隔厚度、E/e'及PDF参数峰值阻力均高于对照,e'低于对照,提示PDF分析可能有助于表征淀粉样心脏病舒张功能。

要点

  • 心脏淀粉样变性患者室间隔厚度较对照增高(14.4±2.6 mm vs. 9.3±1.3 mm,p<0.001)。
  • 患者E/e'较对照升高(18.0±12.9 vs. 7.7±1.3,p=0.001),e'较对照降低(0.06±0.02 m/s vs. 0.09±0.02 m/s,p<0.001)。
  • PDF参数峰值阻力患者大于对照(17.9±5.7 mN vs. 13.1±3.1 mN,p=0.03),其余PDF参数无差异。

核心结论

  • PDF分析显示心脏淀粉样变性患者峰值阻力大于对照,与更严重的舒张功能障碍一致;PDF分析可能有助于表征淀粉样心脏病舒张功能。

研究设计与样本

  • 研究纳入13例淀粉样心脏病患者和13例年龄性别匹配对照,采集经二尖瓣血流脉冲波多普勒超声心动图,每例分析2-3个E波,使用本院开发软件获得9个PDF参数及常规舒张功能参数。

关键影像表现/征象

  • 患者左房面积大于对照(23.7±7.5 cm² vs. 18.5±4.8 cm²,p=0.04)。
  • 患者室间隔厚度大于对照(14.4±2.6 mm vs. 9.3±1.3 mm,p<0.001)。
  • 患者e'低于对照(0.06±0.02 m/s vs. 0.09±0.02 m/s,p<0.001),E/e'高于对照(18.0±12.9 vs. 7.7±1.3,p=0.001)。
  • PDF参数峰值阻力患者大于对照(17.9±5.7 mN vs. 13.1±3.1 mN,p=0.03)。

临床应用与阅片要点

  • PDF分析可能有助于表征淀粉样心脏病的舒张功能(作者结论)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Cardiac amyloidosis is a rare but serious condition with poor survival. One of the early findings by echocardiography is impaired diastolic function, even before the development of cardiac symptoms. Early diagnosis is important, permitting initiation of treatment aimed at improving survival. The parameterized diastolic filling (PDF) formalism entails describing the left ventricular filling pattern during early diastole using the mathematical equation for the motion of a damped harmonic oscillator. We hypothesized that echocardiographic PDF analysis could detect differences in diastolic function between patients with amyloidosis and controls. Pulsed-wave Doppler echocardiography of transmitral flow was measured in 13 patients with amyloid heart disease and 13 age- and gender matched controls. E- waves (2 to 3 per subject) were analyzed using in-house developed software. Nine PDF-derived parameters were obtained in addition to conventional echocardiographic parameters of diastolic function. Compared to controls, cardiac amyloidosis patients had a larger left atrial area (23.7 ± 7.5 cm2 vs. 18.5 ± 4.8 cm2, p = 0.04), greater interventricular septum wall thickness (14.4 ± 2.6 mm vs. 9.3 ± 1.3 mm, p < 0.001), lower e' (0.06 ± 0.02 m/s vs. 0.09 ± 0.02 m/s, p < 0.001) and higher E/e' (18.0 ± 12.9 vs. 7.7 ± 1.3, p = 0.001). The PDF parameter peak resistive force was greater in cardiac amyloidosis patients compared to controls (17.9 ± 5.7 mN vs. 13.1 ± 3.1 mN, p = 0.03), and other PDF parameters did not differ. PDF analysis revealed that patients with cardiac amyloidosis had a greater peak resistive force compared to controls, consistent with a greater degree of diastolic dysfunction. PDF analysis may be useful in characterizing diastolic function in amyloid heart disease.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。