颈总动脉超声与经胸超声心动图在重症监护病房患者心输出量测量中的比较

Common Carotid Artery Sonography Versus Transthoracic Echocardiography for Cardiac Output Measurements in Intensive Care Unit Patients.
PubMed 文献 · J Ultrasound Med · 2017-04-21

本研究纳入148例在8小时内先后接受颈总动脉多普勒超声与经胸超声心动图检查的患者,比较两种方法测得的心输出量。颈总动脉与经胸超声心动图心输出量的总体组内相关系数为0.537,提示中等一致性;在感染性休克、多发伤和呼吸衰竭患者中组内相关系数分别为0.241、0.061和0.095。作者认为颈总动脉心输出量可考虑作为急诊及经胸超声心动图无法获取心输出量时的替代估算方法,但不推荐用于感染性休克、多发伤和呼吸衰竭患者。

要点

  • 颈总动脉与经胸超声心动图心输出量总体组内相关系数为0.537,呈中等一致性。
  • 感染性休克、多发伤、呼吸衰竭患者中两者组内相关系数分别为0.241、0.061、0.095。
  • 作者认为颈总动脉心输出量可考虑用于急诊或经胸超声心动图无法获取时。

核心结论

  • 颈总动脉心输出量与经胸超声心动图心输出量呈中等一致性,可考虑作为急诊及经胸超声心动图无法获取心输出量时的替代估算方法;但在感染性休克、多发伤和呼吸衰竭患者中不推荐使用颈总动脉心输出量。

研究设计与样本

  • 本研究纳入148例在8小时内先后接受颈总动脉多普勒超声检查和经胸超声心动图检查的患者,并将两种方法的心输出量测量结果进行比较。

诊断标准与关键数值

  • 颈总动脉与经胸超声心动图心输出量的总体组内相关系数为0.537;感染性休克患者中两者组内相关系数为0.241,多发伤患者中为0.061,呼吸衰竭患者中为0.095。

临床应用与阅片要点

  • 作者认为颈总动脉心输出量可考虑作为急诊及经胸超声心动图无法获取心输出量时的替代估算方法;作者不推荐在感染性休克、多发伤和呼吸衰竭患者中使用颈总动脉心输出量。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study was designed to test the effectiveness of common carotid artery sonography in comparison with transthoracic echocardiography (TTE) for cardiac output measurements to provide an easier alternative for cardiac output monitoring in the intensive care unit.

METHODS: This study included 148 patients who had common carotid artery Doppler examinations and TTE performed within 8 hours of each other, and the cardiac output measurement results were compared with each other.

RESULTS: The mean age of the participants ± SD was 56.8 ± 16.2 years, with male patients composing 54.7% of the cohort. There was no significant difference in carotid and TTE cardiac output between different sexes, age groups, patients with and without mechanical ventilation, and primary indication groups. The overall intraclass correlation coefficient between the carotid and TTE cardiac output was 0.537. In patients with septic shock, multiple trauma, and respiratory failure, the intraclass correlation coefficients between TTE and carotid cardiac output were 0.241, 0.061, and 0.095, respectively.

CONCLUSIONS: Carotid cardiac output shows moderate agreement with TTE cardiac output; thus, its use may be considered as an alternative for estimating cardiac output in emergencies and when TTE cardiac output is unobtainable. However, in patients with septic shock, multiple trauma, and respiratory failure, the use of carotid cardiac output is not recommended.