临床环境中冠状动脉CT血管造影低剂量与超低剂量对比剂方案:与标准剂量方案的定量与定性比较

A low-dose and an ultra-low-dose contrast agent protocol for coronary CT angiography in a clinical setting: quantitative and qualitative comparison to a standard dose protocol.
PubMed 文献 · Br J Radiol · 2017-05-25

在临床环境中使用256层CT对120例连续患者分别采用低剂量(60例,35-55 ml)或超低剂量(60例,25-45 ml)对比剂方案,并与20例标准剂量(40-105 ml)方案患者进行回顾性比较。低剂量方案(中位45 ml)的冠状动脉衰减与标准剂量方案(中位70 ml)无显著差异,而超低剂量方案(中位35 ml)衰减显著低于低剂量和标准剂量方案,且冠状动脉血管衰减不足的患者比例显著更高(37% vs 5%和10%)。结论认为低剂量对比剂方案可行,超低剂量方案在临床实践中仍具挑战性。

要点

  • 低剂量对比剂方案(中位45 ml)的冠状动脉衰减与标准剂量方案(中位70 ml)无显著差异。
  • 超低剂量方案(中位35 ml)冠状动脉衰减显著低于低剂量和标准剂量方案,视觉图像质量无显著差异。
  • 超低剂量方案冠状动脉血管衰减不足患者比例(37%)显著高于标准剂量(5%)和低剂量(10%)方案。

核心结论

  • 在临床环境中,中位体积45 ml的低剂量对比剂方案对于最新一代256层冠状动脉CT血管造影是可行的,因其产生的衰减与标准剂量方案相当;而超低剂量方案的实施仍具挑战性。

研究设计与样本

  • 回顾性比较研究,纳入120例连续患者接受低剂量(60例,35-55 ml)或超低剂量(60例,25-45 ml)对比剂方案,并与20例连续接受标准剂量(40-105 ml)方案的患者进行回顾性比较,使用256层CT扫描仪,对比剂用量根据体重指数调整。

关键影像表现/征象

  • 视觉评估的图像质量在各方案间无显著差异。
  • 超低剂量方案(中位对比剂体积35 ml)的冠状动脉节段衰减为316 ± 52 HU,显著低于低剂量方案(中位45 ml)的363 ± 60 HU和标准剂量方案(中位70 ml)的359 ± 52 HU(p < 0.001)。
  • 低剂量方案与标准剂量方案的衰减无显著差异。

诊断标准与关键数值

  • 超低剂量方案冠状动脉血管衰减不足的患者比例为37%,显著高于标准剂量方案的5%和低剂量方案的10%(p < 0.001)。
  • 标准剂量方案与低剂量方案的冠状动脉血管衰减不足患者比例无显著差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the impact of a low-dose (LD) and an ultra-LD (ULD) contrast protocol for coronary CT angiography on qualitative and quantitative image parameters in a clinical setting.

METHODS: We scanned 120 consecutive patients with a 256-slice CT scanner applying a LD (60 patients, 35-55 ml) or ULD (60 patients, 25-45 ml) contrast protocol adapted to the body mass index. Visually assessed image quality and attenuation measured in each coronary segment were retrospectively compared in 20 consecutive patients scanned with a normal-dose (ND, 40-105 ml) contrast protocol.

RESULTS: Visually assessed image quality did not differ significantly among protocols. By contrast, attenuation obtained from the ULD protocol (median contrast volume 35 ml) differed significantly from the LD (median 45 ml) and ND (median 70 ml) protocols in the coronary segments (316 ± 52 vs 363 ± 60 and 359 ± 52 HU, p < 0.001). Attenuation did not differ significantly between the LD and ND protocol. The proportion of patients with inadequate coronary vessel attenuation was significantly higher (p < 0.001) in the ULD protocol (37%) than in the ND (5%) and LD (10%) protocols but did not differ significantly between the ND and LD protocols.

CONCLUSION: In a clinical setting, a LD contrast protocol with a median volume of 45 ml is feasible for the latest generation 256-slice coronary CT angiography as it yields attenuation comparable to a ND protocol. By contrast, the implementation of an ULD protocol remains challenging. Advances in knowledge: Although not perceived by the naked eye, an ULD contrast protocol in a clinical setting yields attenuation below a threshold for diagnostic image quality.

来源:Br J Radiol,查看原文。版权归原作者所有。