惯性空化超声联合微泡联合组织型纤溶酶原激活剂在微血管阻塞体外模型中改善再灌注疗效
本研究在体外微血管阻塞模型中,比较脉冲超声(1 MHz)的惯性空化方案与稳定空化方案联合或不联合组织型纤溶酶原激活剂对静脉型和动脉型微血栓的溶栓再灌注效果。结果显示惯性空化联合组织型纤溶酶原激活剂的再灌注疗效显著优于单用组织型纤溶酶原激活剂、单用惯性空化、稳定空化及稳定空化联合组织型纤溶酶原激活剂,提示两者对两类血栓均有溶栓协同作用。
要点
- 惯性空化联合组织型纤溶酶原激活剂对静脉型和动脉型微血栓的再灌注疗效均显著优于其他方案。
- 惯性空化方案(1.0 MPa、1000周期、0.33 Hz)较既往体外研究(1.5 MPa、5000周期)超声能量减少90%。
- 微泡悬液浓度为2×10⁶个/mL,与脉冲超声同步输注。
核心结论
- 惯性空化联合组织型纤溶酶原激活剂对静脉型和动脉型微血栓的再灌注疗效显著优于单用组织型纤溶酶原激活剂、单用惯性空化、稳定空化及稳定空化联合组织型纤溶酶原激活剂,提示两者存在溶栓协同作用。
- 本研究所用惯性空化方案较既往体外研究(1.5 MPa、5000周期、不联合组织型纤溶酶原激活剂)超声能量减少90%。
研究设计与样本
- 体外研究,采用孔径40 μm的滤网模拟微血管阻塞,分别灌注静脉型和动脉型微血栓。
- 脉冲超声频率1 MHz,惯性空化方案为1.0 MPa、1000周期、0.33 Hz,稳定空化方案为0.23 MPa、20%占空比、0.33 Hz。
- 微泡悬液浓度2×10⁶个/mL,与超声同步输注;在联合或不联合组织型纤溶酶原激活剂的条件下测试再灌注疗效。
诊断标准与关键数值
- 惯性空化联合组织型纤溶酶原激活剂的再灌注疗效显著优于单用组织型纤溶酶原激活剂、单用惯性空化、稳定空化及稳定空化联合组织型纤溶酶原激活剂,对静脉型和动脉型微血栓均如此。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
We have previously reported that long-tone-burst, high-mechanical-index ultrasound (US) and microbubble (MB) therapy can restore perfusion in both in vitro and in vivo models of microvascular obstruction (MVO). Addition of MBs to US has been found to potentiate the efficacy of thrombolytics on large venous thrombi; however, the optimal US parameters for achieving microvascular reperfusion of MVO caused by microthrombi, when combined with tissue plasminogen activator (tPA), are unknown. We sought to elucidate the specific effects of US, with and without tPA, for effective reperfusion of MVO in an in vitro model using both venous and arterial microthrombi. Venous- and arterial-type microthrombi were infused onto a mesh with 40-μm pores to simulate MVO. Pulsed US (1 MHz) was delivered with inertial cavitation (IC) (1.0 MPa, 1000 cycles, 0.33 Hz) and stable cavitation (SC) US (0.23 MPa, 20% duty cycle, 0.33 Hz) regimes while MB suspension (2 × 106 MBs/mL) was infused. The efficacy of sonoreperfusion with these parameters was tested with and without tPA. Sonoreperfusion efficacy was significantly greater for IC + tPA compared with tPA alone, IC, SC and SC + tPA, suggesting lytic synergism between tPA and US for both venous- and arterial-type microthrombi. In contrast to our previous in vitro studies using 1.5 MPa at 5000 US cycles without tPA, the IC regime employed herein used 90% less US energy. These findings suggest an IC regime can be used with tPA synergistically to achieve a high degree of fibrinolysis for both thrombus types.
引用
- Goyal A, Yu FTH, Tenwalde MG, et al. Inertial Cavitation Ultrasound with Microbubbles Improves Reperfusion Efficacy When Combined with Tissue Plasminogen Activator in an In Vitro Model of Microvascular Obstruction. Ultrasound Med Biol. 2017. PMID: 28395964. doi:10.1016/j.ultrasmedbio.2017.02.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。