心房颤动:全心脏230微米空间分辨率CT扫描仪行冠状动脉CT血管造影的诊断准确性

Atrial Fibrillation: Diagnostic Accuracy of Coronary CT Angiography Performed with a Whole-Heart 230-µm Spatial Resolution CT Scanner.
PubMed 文献 · Radiology · 2017-04-26

前瞻性纳入166例患者(83例心房颤动,83例窦性心律),均行冠状动脉CT血管造影与有创冠状动脉造影对照。全心脏CT在慢性心房颤动患者中图像质量高、辐射剂量低、诊断准确性高,诊断性能与窦性心律患者相似。

要点

  • 慢性心房颤动患者冠状动脉可判读性达98.5%,与窦性心律患者的98.4%无显著差异(P=0.96)。
  • 基于节段分析,慢性心房颤动组检测冠状动脉狭窄超过50%的敏感度和特异度分别为96.4%和98.7%。
  • 基于患者分析,慢性心房颤动组敏感度和特异度分别为95.2%和97.6%。

核心结论

  • 全心脏CT在慢性心房颤动患者中可实现高图像质量、低辐射暴露和高诊断准确性的冠状动脉评估,诊断性能与窦性心律患者相似。

研究设计与样本

  • 前瞻性研究,2015年3月至2016年2月连续纳入166例患者(83例心房颤动,83例窦性心律),均行有创冠状动脉造影和全心脏CT扫描仪冠状动脉CT血管造影,以有创冠状动脉造影为参考标准。

诊断标准与关键数值

  • 基于节段分析,慢性心房颤动组检测冠状动脉狭窄超过50%的敏感度为96.4%、特异度为98.7%(P=0.98);窦性心律组敏感度为95.6%、特异度为98.1%(P=0.32)。
  • 基于患者分析,慢性心房颤动组敏感度为95.2%、特异度为97.6%(P=0.95);窦性心律组敏感度为97.8%、特异度为94.7%(P=0.93)。
  • 冠状动脉可判读性:心房颤动组98.5%,窦性心律组98.4%(P=0.96)。
  • 扫描期间平均心率:心房颤动组83次/分±21,窦性心律组63次/分±14(P<.01)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To assess image quality, interpretability, diagnostic accuracy, and radiation exposure of a computed tomography (CT) scanner with 16-cm coverage and 230-µm spatial resolution at coronary artery evaluation in patients with atrial fibrillation (AF) by using invasive coronary angiography (ICA) as the reference method and to compare the results with those obtained in patients with sinus rhythm (SR). Materials and Methods Written informed consent and institutional ethics committee approval were obtained. Between March 2015 and February 2016, 166 consecutive patients were prospectively enrolled (83 with AF, 83 with SR). They underwent ICA and coronary CT angiography performed with a whole-heart CT scanner. Image quality, coronary segment interpretability, effective dose (ED), and diagnostic accuracy were assessed at CT angiography and were compared with those attained with ICA. Diagnostic performance of the groups was compared with the pairwise McNemar test. Results Mean heart rate during scanning was 83 beats per minute ± 21 (standard deviation) in the AF group and 63 beats per minute ± 14 in the SR group (P < .01). Coronary interpretability was 98.5% in the AF group and 98.4% in the SR group (P = .96). In a segment-based analysis, sensitivity and specificity in the detection of coronary stenosis of more than 50% compared with detection of ICA were 96.4% and 98.7%, respectively, in the chronic AF group (P = .98) and 95.6% and 98.1%, respectively, in the SR group (P = .32). In a patient-based analysis, sensitivity and specificity were 95.2% and 97.6%, respectively, in the chronic AF group (P = .95) and 97.8% and 94.7%, respectively, in the SR group (P = .93). Conclusion Whole-heart CT enables evaluation of coronary arteries with high image quality, low radiation exposure, and high diagnostic accuracy in patients with chronic AF, with a diagnostic performance similar to that in patients with SR. © RSNA, 2017 Online supplemental material is available for this article.