文献速递心血管CT

256排探测器冠状动脉CT血管成像在高心率患者单心动周期内的诊断性能:初步研究

Diagnostic performance of 256-row detector coronary CT angiography in patients with high heart rates within a single cardiac cycle: a preliminary study.
PubMed 文献 · Clin Radiol · 2017-04-05

回顾性纳入84例心率≥75次/分疑似冠心病患者,采用256排16cm探测器CT行前瞻性心电触发单心动周期CCTA,以有创冠状动脉造影为参考。98.9%的冠状动脉节段图像质量可诊断,按节段、血管、患者分析的敏感度分别为91.5%、95.2%、100%,平均有效剂量1.9±1 mSv。

要点

  • 高心率(≥75次/分)患者单心动周期CCTA中98.9%(1044/1056)的冠状动脉节段图像质量可满足诊断。
  • 以ICA为参考,CCTA检出≥50%狭窄的患者水平敏感度100%、特异度85.7%、阳性预测值93.3%、阴性预测值100%。
  • 平均有效剂量1.9±1 mSv,采用自动管电压选择(100或120 kV)和管电流调制技术。

核心结论

  • 使用256排探测器CT结合snapshot freeze(SSF)技术,可在高心率患者单心动周期内完成CCTA,获得高诊断价值图像且辐射剂量低。

研究设计与样本

  • 回顾性纳入84例连续有症状疑似冠心病患者(平均年龄60.4±9.1岁,52例男性),心率≥75次/分,均行CCTA和有创冠状动脉造影(ICA)。采用256排16 cm探测器CT(Revolution CT,GE Healthcare)行前瞻性心电触发单心动周期容积CCTA,自动管电压选择(kV Assist选择100或120 kV)和管电流调制(Smart mA),图像以50%自适应统计迭代重建-V(ASiR-V)重建。

诊断标准与关键数值

  • 由两名评价者基于18节段模型采用4分法评估冠状动脉节段图像质量;以ICA检出≥50%狭窄为参考,CCTA诊断≥50%直径狭窄的敏感度、特异度、阳性预测值、阴性预测值分别为:按节段91.5%、95.6%、77.7%、98.5%;按血管95.2%、93.5%、87%、97.7%;按患者100%、85.7%、93.3%、100%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the image quality and diagnostic performance of coronary computed tomography angiography (CCTA) in patients with high heart rate within a single cardiac cycle using a 256-row detector CT system.

MATERIALS AND METHODS: Eighty-four consecutive symptomatic patients (mean age 60.4±9.1 years, 52 men) with suspected coronary artery disease and heart rate ≥75 beats/min undergoing CCTA and invasive coronary angiography (ICA) were enrolled retrospectively. Prospective electrocardiography (ECG)-triggered volume CCTA within a single cardiac cycle was performed using a 256-row, 16 cm detector CT system (Revolution CT, GE Healthcare) using automated tube voltage selection (kV Assist selecting 100 or 120 kV) and tube current modulation (Smart mA) techniques, with images reconstructed using 50% of adaptive statistical iterative reconstruction-V (ASiR-V). The image quality of coronary artery segments was evaluated by two reviewers using a four-point scale based on 18-segment model. The diagnostic accuracy of CCTA to detect ≥50% stenosis on ICA was analysed. The sensitivity, specificity, positive predictive value, and negative predictive value of CCTA to detect a ≥50% diameter stenosis on ICA were calculated from the chi-squared test of the contingency table on a per-segment, per-vessel, and per-patient basis.

RESULTS: The body mass index was 25.6±3.5 kg/m2; the HR was 82.8±7.9 beats/min, and the mean HR variability was 8.3±4.8 beats/min. All of the coronary artery segments, 98.9% (1044/1056) of coronary segments were rated as having diagnostic image quality. The diagnostic sensitivity, specificity, positive predictive value, and negative predictive value of CCTA, were 91.5%, 95.6%, 77.7%, and 98.5% on a per-segment basis; 95.2%, 93.5%, 87%, and 97.7% on a per-vessel basis; 100%, 85.7%, 93.3%, and 100% on per-patient basis, respectively. The mean effective dose was 1.9±1 mSv.

CONCLUSIONS: CCTA using a 256-detector row CT with the snapshot freeze (SSF) technique can be performed in a single cardiac cycle with acquisition of images with high diagnostic value and low radiation dose in patients with high heart rates.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Liang J, Wang H, Xu L, et al. Diagnostic performance of 256-row detector coronary CT angiography in patients with high heart rates within a single cardiac cycle: a preliminary study. Clin Radiol. 2017. PMID: 28390673. doi:10.1016/j.crad.2017.03.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。