文献速递心血管MR

心房颤动:左心房压力与左心耳排空的关系——基于速度编码心脏MR成像的研究

Atrial Fibrillation: Relationship between Left Atrial Pressure and Left Atrial Appendage Emptying Determined with Velocity-encoded Cardiac MR Imaging.
PubMed 文献 · Radiology · 2017-04-10

回顾性纳入77例心房颤动患者,先后行心脏MR成像与导管测压,用速度编码MR测量左心耳排空最大血流量;左心耳排空与峰值左心房压呈显著负相关,峰值左心房压≥19 mm Hg组左心耳排空低于<19 mm Hg组,评估左心房压升高的左心耳排空截断值为47 mL/秒。

要点

  • 左心耳排空(LAA emptying)与峰值左心房压呈显著负相关(P < .01)。
  • 峰值左心房压≥19 mm Hg组左心耳排空均值39.3 mL/秒±13.7,低于<19 mm Hg组的61.2 mL/秒±20.7(P < .01)。
  • 正常窦性心律下评估左心房压升高,左心耳排空截断值47 mL/秒的敏感度75.0%、特异度87.5%。

核心结论

  • 用速度编码MR成像评估左心耳排空有助于评估心房颤动患者的左心房压状态。

研究设计与样本

  • 回顾性研究,经机构审查委员会批准并获患者书面知情同意,纳入77例心房颤动患者(平均年龄57.8岁±9.8,范围31-76岁),先后行心脏MR成像与导管测压;速度编码MR成像垂直于左心耳开口采集,以左心耳至左心房的最大血流量(mL/秒)定义左心耳排空;按峰值左心房压≥19 mm Hg与<19 mm Hg分为左心房压升高组与未升高组,用受试者工作特征曲线确定左心耳排空评估左心房压状态的截断值。

关键影像表现/征象

  • 左心耳排空与峰值左心房压呈显著负相关(P < .01)。
  • 左心房压升高组左心耳排空显著低于未升高组(均值39.3 mL/秒±13.7 vs 61.2 mL/秒±20.7,P < .01)。

诊断标准与关键数值

  • 以速度编码MR评估正常窦性心律下左心房压升高时,左心耳排空截断值47 mL/秒的敏感度75.0%、特异度87.5%、阳性预测值66.6%、阴性预测值91.3%。
  • 多因素分析中,低左心耳排空(<47 mL/秒)的比值比与左心房压升高独立相关。

临床应用与阅片要点

  • 速度编码MR成像垂直于左心耳开口测量左心耳至左心房最大血流量,可无创评估左心房压状态。
  • 左心耳排空<47 mL/秒提示左心房压升高的可能,阴性预测值91.3%对排除左心房压升高有参考价值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To investigate the relationship between left atrial appendage (LAA) blood flow determined with cardiac magnetic resonance (MR) imaging and left atrial pressure (LAP) estimated from invasive catheter measurements in patients with atrial fibrillation (AF). Materials and Methods This retrospective study was approved by the institutional review board, and patients provided written informed consent. Seventy-seven patients with AF (mean age, 57.8 years ± 9.8; range, 31-76 years) underwent cardiac MR imaging and catheter-based measurement of LAP, sequentially. Velocity-encoded (VENC) cardiac MR imaging was performed perpendicular to the ostium of the LAA. The maximum blood flux (in milliliters per second) from the LAA to the left atrium (LA) as determined with VENC MR imaging was defined as LAA emptying. Patients were classified into two groups: those with elevated LAP (peak LAP ≥19 mm Hg) and those with nonelevated LAP (peak LAP <19 mm Hg). Receiver operating characteristic curves were used to determine the cut-off values of LAA emptying in the assessment of the LAP status. Results LAA emptying showed a significantly inverse relationship (P < .01) with the peak LAP. Patients with elevated LAP showed significantly less LAA emptying than did patients with nonelevated LAP (mean, 39.3 mL/sec ± 13.7 vs 61.2 mL/sec ± 20.7, respectively; P < .01). In the assessment of elevated LAP with use of VENC MR imaging in normal sinus rhythm, the LAA emptying cut-off value of 47 mL/sec had a sensitivity of 75.0%, specificity of 87.5%, positive predictive value of 66.6%, and negative predictive value of 91.3%. At multivariate analysis, the odds ratio of low LAA emptying (<47 mL/sec) was independently associated with elevated LAP. Conclusion Evaluation of LAA emptying with use of VENC MR imaging is helpful for assessing the LAP status of patients with AF. © RSNA, 2017.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Hwang SH, Roh SY, Shim J, et al. Atrial Fibrillation: Relationship between Left Atrial Pressure and Left Atrial Appendage Emptying Determined with Velocity-encoded Cardiac MR Imaging. Radiology. 2017. PMID: 28394753. doi:10.1148/radiol.2017161654

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。