经导管主动脉瓣置换术后起搏器植入的高预测性风险模型
在Cedars-Sinai心脏研究所单中心回顾性纳入240例接受第三代球囊扩张瓣膜TAVR的重度主动脉瓣狭窄患者,精确刻画主动脉瓣复合体钙化分布。无冠状窦装置着陆区钙化体积是无冠窦装置着陆区钙化体积独立预测因子,结合短膜部室间隔、术前右束支传导阻滞及心室植入深度构建的风险模型c-statistic达0.92、敏感度94.3%、特异度83.8%、阴性预测值98.8%。作者指出该模型需未来前瞻性多中心研究验证。
要点
- 无冠状窦装置着陆区钙化体积是无冠窦装置着陆区钙化体积新发永久起搏器植入的独立预测因子。
- 联合右束支传导阻滞、短膜部室间隔及植入深度与膜部室间隔长度差值的模型AUC 0.92、敏感度94.3%、特异度83.8%。
- 模型阴性预测值达98.8%,有助于识别起搏器植入低风险患者。
核心结论
- 通过精确刻画主动脉瓣复合体钙化分布,无冠状窦装置着陆区钙化体积是第三代球囊扩张瓣膜TAVR术后新发永久起搏器植入的独立预测因子,短膜部室间隔长度、术前右束支传导阻滞及心室植入深度为重要协同风险因素,该风险模型需未来前瞻性多中心研究验证。
研究设计与样本
- 单中心回顾性研究,共纳入240例接受第三代球囊扩张瓣膜TAVR并完成对比剂CT检查的重度主动脉瓣狭窄患者,按瓣叶扇区和区域精确刻画主动脉瓣复合体钙化。
诊断标准与关键数值
- 总体新发永久起搏器植入率为14.6%;多因素分析纳入术前第三代球囊扩张瓣膜TAVR、右束支传导阻滞、较短膜部室间隔长度及无冠状窦装置着陆区钙化体积;存在3项术前危险因素时模型c-statistic为AUC 0.88、敏感度77.1%、特异度87.1%、阴性预测值95.7%;加入装置深度与膜部室间隔长度差值的操作因素并结合右束支传导阻滞及无冠状窦装置着陆区钙化体积后,c-statistic升至0.92、敏感度94.3%、特异度83.8%、阴性预测值98.8%。
局限性
- 原文明确为单中心、回顾性研究。
- 该风险模型需未来前瞻性多中心研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study sought to develop a robust and definitive risk model for new permanent pacemaker implantation (PPMI) after SAPIEN 3 (third generation balloon expandable valve) (Edwards Lifesciences, Irvine, California) transcatheter aortic valve replacement (third generation balloon expandable valve TAVR), including calcification in the aortic-valvular complex (AVC).
BACKGROUND: The association between calcium in the AVC and need for PPMI is poorly delineated after third generation balloon expandable valve TAVR.
METHODS: At Cedars-Sinai Heart Institute in Los Angeles, California, a total of 240 patients with severe aortic stenosis underwent third generation balloon expandable valve TAVR and had contrast computed tomography. AVC was characterized precisely by leaflet sector and region.
RESULTS: The total new PPMI rate was 14.6%. On multivariate analysis for predictors of PPMI, pre-procedure third generation balloon expandable valve TAVR, right bundle branch block (RBBB), shorter membranous septum (MS) length, and noncoronary cusp device-landing zone calcium volume (NCC-DLZ CA) were included. Predictive probabilities were generated using this logistic regression model. If 3 pre-procedural risk factors were present, the c-statistic of the model for PPMI was area under the curve of 0.88, sensitivity of 77.1%, and specificity of 87.1%; this risk model had high negative predictive value (95.7%). The addition of the procedural factor of device depth to the model, with the parameter of difference between implantation depth and MS length, combined with RBBB and NCC-DLZ CA increased the c-statistic to 0.92, sensitivity to 94.3%, specificity to 83.8%, and negative predictive value to 98.8% CONCLUSIONS: By using a precise characterization of distribution of calcification in the AVC in a single-center, retrospective study, NCC-DLZ CA was found to be an independent predictor of new PPMI post-third generation balloon expandable valve TAVR. The findings also reinforce the importance of short MS length, pre-existing RBBB, and ventricular implantation depth as important synergistic PPMI risk factors. This risk model will need validation by future prospective multicenter studies.
引用
- Maeno Y, Abramowitz Y, Kawamori H, et al. A Highly Predictive Risk Model for Pacemaker Implantation After TAVR. JACC Cardiovasc Imaging. 2017. PMID: 28412434. doi:10.1016/j.jcmg.2016.11.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。