文献速递心血管CT

第三代双源CT涡轮高螺距冠状动脉成像的优势与局限性

Strengths and limitations of coronary angiography with turbo high-pitch third-generation dual-source CT.
PubMed 文献 · Clin Radiol · 2017-04-08

回顾性单中心分析229例连续患者,采用涡轮高螺距模式行CT冠状动脉成像,中位有效辐射剂量0.6 mSv,98.1%的冠状动脉节段图像质量可诊断;Agatston评分与可诊断图像质量独立相关,心率、BMI和心律失常与此无关。

要点

  • 涡轮高螺距CT冠状动脉成像中位有效辐射剂量0.6 mSv,70 kV亚组为0.3 mSv。
  • 98.1%的冠状动脉节段图像质量可诊断,Agatston评分与可诊断图像质量独立相关。
  • Agatston评分>600的患者可诊断节段比例显著下降。

核心结论

  • 涡轮高螺距模式可实现极低辐射剂量的CT冠状动脉成像,最适用于非肥胖、窦性心律稳定≤65次/分且钙化评分≤600的患者。

研究设计与样本

  • 回顾性单中心分析,连续纳入229例行CT冠状动脉成像的患者,采用涡轮高螺距模式采集增强容积数据集,由三名盲法读片者将冠状动脉节段图像质量分为可诊断或不可诊断。

诊断标准与关键数值

  • 至少一名读片者既不能排除也不能确认显著狭窄的节段被判定为不可诊断。
  • 3,678个冠状动脉节段中98.1%图像质量可诊断。
  • Agatston评分与可诊断图像质量独立相关(B=0.34;p=0.02)。
  • Agatston评分>600的患者可诊断冠状动脉节段比例显著下降(p=0.003)。
  • 心率、BMI和心律失常存在与可诊断图像质量无独立关联。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To define practical limitations of diagnostic image quality for recently introduced turbo high-pitch scan mode (THP) in third-generation dual-source computed tomography (CT).

MATERIALS AND METHODS: Two hundred and twenty-nine consecutive patients undergoing CT coronary angiography were included in this retrospective single-centre analysis. A contrast-enhanced volume dataset was acquired in THP. Image quality of coronary segments was classified as diagnostic or non-diagnostic by three blinded readers. Segments were stated as non-diagnostic if at least one of three readers could neither exclude nor confirm significant stenoses. Multivariable logistic regression was used to assess relationships between number of non-diagnostic segments and common influencing factors.

RESULTS: Median effective radiation dose was 0.6 (interquartile range [IQR], 0.4-0.8) mSv overall and 0.3 (IQR, 0.3-0.4) mSv in the 70 kV subgroup of this middle aged, predominantly pre-obese cohort (age: 61 [IQR, 52-67] years; body mass index [BMI]: 26 [IQR, 23-29] kg/m2) with a low-moderate median Agatston score (AS) 0 (IQR, 0-70). Diagnostic image quality was found in 98.1% of 3,678 coronary segments. AS was independently associated with diagnostic image quality (B=0.34; p=0.02), whereas heart rate, BMI, and presence of arrhythmia were not. The portion of diagnostic coronary segments decreased slightly in obese patients with heart rates >65 beats/min and dropped significantly in patients with an AS >600 (p=0.003).

CONCLUSION: THP enables CT coronary angiography with minimal radiation exposure and is most appropriate in non-obese patients with stable sinus rhythm ≤65 beats/min and a calcium score ≤600.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Ochs MM, Andre F, Korosoglou G, et al. Strengths and limitations of coronary angiography with turbo high-pitch third-generation dual-source CT. Clin Radiol. 2017. PMID: 28395916. doi:10.1016/j.crad.2017.03.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。