文献速递胸部技术与安全CT

自动化追踪登记系统对偶发肺结节追踪失败率的影响

Effect of an Automated Tracking Registry on the Rate of Tracking Failure in Incidental Pulmonary Nodules.
PubMed 文献 · J Am Coll Radiol · 2017-04-21

本机构开发并实施自动化肺结节登记追踪系统,并在另外八家退伍军人事务医疗中心推广,纳入超过10000例患者。回顾性分析两家大学附属退伍军人事务医疗中心实施前后各200份连续CT报告,追踪失败率从实施前的74%降至实施后的10%(P < .001)。

要点

  • 自动化肺结节登记追踪系统实施后,追踪失败率从74%降至10%(P < .001)。
  • 可疑结节定义为放射科医生记录为潜在恶性或建议随访影像的任何实性或磨玻璃结节,且<3 cm。
  • 年龄、结节大小、数量和结节特征是追踪失败的显著预测因素。

核心结论

  • 自动化肺结节登记追踪系统可推广至其他医疗机构,并显著降低追踪失败率。

研究设计与样本

  • 回顾性研究,在两家大学附属退伍军人事务医疗中心实施前后各回顾200份连续CT报告;系统已推广至另外八家退伍军人事务医疗中心,纳入超过10000例患者。

诊断标准与关键数值

  • 可疑结节定义为任何结节,实性或磨玻璃,<3 cm,且放射科医生记录为潜在恶性或建议随访影像。
  • 追踪失败定义为可疑结节无随访影像或随访延迟(与已发表指南相比)。

临床应用与阅片要点

  • 实施自动化肺结节登记追踪系统后,追踪失败率从74%降至10%(P < .001)。
  • 年龄、结节大小、数量和结节特征是追踪失败的显著预测因素。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Following incidental lung nodules with interval CT scanning is an accepted method to detect early lung cancer, but delayed tracking or failure to track is reported in up to 40% of patients.

METHODS: Our institution developed and implemented an automated lung nodule registry tracking system. This system uses a code at the time that a suspicious nodule is discovered to populate the registry. Suspicious nodules were defined as any nodule, solid or ground glass, <3 cm that the radiologist recorded as a potential malignancy or recommended for follow-up imaging. We exported the system to eight other Veterans Administration Medical Centers (VAMCs) with over 10,000 patients enrolled. We retrospectively reviewed 200 sequential CT scan reports containing incidental nodule(s) from two tertiary care university-affiliated VAMCs, both before and after the implementation of the registry tracking system. The primary outcome was the rate of tracking failure, defined as suspicious nodules that had no follow-up imaging or whose follow-up was delayed when compared with published guidelines. Secondary outcomes were predictors of tracking failure and reasons for tracking failure.

RESULTS: After implementation of the registry tracking system in the two VAMCs, we found a significant decrease in tracking failure, from a preimplementation rate of 74% to a postimplementation rate of 10% (P < .001). We found that age, nodule size, number, and nodule characteristics were significant predictors.

CONCLUSIONS: The automated lung nodule registry tracking system can be exported to other health care facilities and significantly reduces the rate of tracking failure.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Shelver J, Wendt CH, McClure M, et al. Effect of an Automated Tracking Registry on the Rate of Tracking Failure in Incidental Pulmonary Nodules. J Am Coll Radiol. 2017. PMID: 28434846. doi:10.1016/j.jacr.2017.02.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。