文献速递胸部骨肌技术与安全MR

非小细胞肺癌骨转移的动态对比增强MR成像参数:原发肺癌EGFR突变与无突变病灶的比较

Dynamic Contrast-enhanced MR Imaging Parameters in Bone Metastases from Non-Small Cell Lung Cancer: Comparison between Lesions with and Lesions without Epidermal Growth Factor Receptor Mutation in Primary Lung Cancer.
PubMed 文献 · Radiology · 2017-04-27

回顾性纳入47例原发非小细胞肺癌伴骨转移患者(EGFR突变阳性27例、阴性26例),比较两组骨转移灶的DCE-MRI参数。两位阅片者间一致性高(Ktrans ICC=0.95、kep ICC=0.97、ve ICC=0.91);EGFR突变阳性组Ktrans显著更高(阅片者1 P=.039,阅片者2 P=.032),kep仅在一位阅片者评估中差异有统计学意义(阅片者2 P=.048,阅片者1 P=.058),ve无显著差异(P=.873、P=.889)。作者认为参数差异可能归因于EGFR信号通路激活所致血管生成相关的血管结构差异。

要点

  • EGFR突变阳性组骨转移灶Ktrans显著高于阴性组(P=.039与P=.032)。
  • kep在突变阳性组也较高,但仅一位阅片者评估达统计学显著(P=.048,另一位P=.058)。
  • ve在两组间无显著差异(P=.873与P=.889)。

核心结论

  • 原发NSCLC EGFR突变阳性与阴性患者的骨转移灶在DCE-MRI参数上存在差异,可能归因于EGFR信号通路激活刺激血管生成所致的血管结构差异。

研究设计与样本

  • 经机构审查委员会批准的回顾性研究,纳入2012年11月至2016年3月间47例原发NSCLC且EGFR突变状态明确、因骨转移行DCE-MRI的患者(EGFR突变阳性27例、阴性26例),由两位放射科医师独立使用图像处理软件分析Ktrans、kep、ve,组间比较采用Mann-Whitney U检验,阅片者间一致性采用组内相关系数计算。

诊断标准与关键数值

  • Ktrans在EGFR突变阳性组显著高于阴性组(阅片者1 P=.039,阅片者2 P=.032)。
  • kep在EGFR突变阳性组也较高,但仅在阅片者2评估中达统计学显著(P=.048),阅片者1评估为P=.058。
  • ve在两组间无显著差异(阅片者1 P=.873,阅片者2 P=.889)。
  • 阅片者间一致性:Ktrans ICC=0.95,kep ICC=0.97,ve ICC=0.91。

临床应用与阅片要点

  • 作者认为,原发NSCLC EGFR突变阳性与阴性患者骨转移灶的DCE-MRI参数差异可能归因于EGFR信号通路激活刺激血管生成所致的血管结构差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To compare dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging parameters between metastatic bone lesions with and without the epidermal growth factor receptor (EGFR) mutation in consecutive patients with primary non-small cell lung cancer (NSCLC). Materials and Methods This study was approved by the institutional review board. Forty-seven patients with NSCLC and a confirmed EGFR mutation status (27 patients were positive and 26 were negative for EGFR mutation), who underwent DCE MR imaging for bone metastases between November 2012 and March 2016, were included in this study. Two radiologists independently analyzed the volume transfer constant (Ktrans), reflux rate (kep), and volume fraction of the extravascular extracellular matrix (ve) using image processing software. Intergroup comparisons of the mean measured parameters were performed with the Mann-Whitney U test. Interobserver agreement was calculated with the intraclass correlation coefficient. Results There was a high level of agreement between the two reviewers for all three parameters (intraclass correlation coefficient = 0.95 for Ktrans, 0.97 for kep, and 0.91 for ve). Ktrans was significantly higher in the EGFR mutation-positive group (P = .039 for reviewer 1, P = .032 for reviewer 2). kep was also higher in the EGFR mutation-positive group but showed statistical significance only in the evaluation performed by one reviewer (P = .048 for reviewer 2, P = .058 for reviewer 1). No significant difference was observed in ve (P = .873 for reviewer 1, P = .889 for reviewer 2). Conclusion The differences in the DCE MR imaging parameters between metastatic bone lesions with and without EGFR mutations in primary NSCLC may be attributed to differences in the vascular structure related to angiogenesis stimulated by the activation of the EGFR signaling pathway. © RSNA, 2017 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Kim HS, Yoon YC, Kwon S, et al. Dynamic Contrast-enhanced MR Imaging Parameters in Bone Metastases from Non-Small Cell Lung Cancer: Comparison between Lesions with and Lesions without Epidermal Growth Factor Receptor Mutation in Primary Lung Cancer. Radiology. 2017. PMID: 28448232. doi:10.1148/radiol.2017162336

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。