本研究纳入16例慢性血栓栓塞性肺动脉高压患者的30次连续介入、共99个治疗肺动脉段,用二维灌注血管造影(2D-PA)后处理DSA图像,评估球囊肺动脉成形术(BPA)前后肺实质灌注变化。BPA后肺血流分级评分改善(p<0.0001),TTP实质/流入比缩短10%(p=0.0002),PD实质/流入比增加46%(p<0.0001),AUC实质/流入比增加36%(p<0.0001);肺血流分级评分变化与PD实质/流入比变化(ρ=0.48,p<0.0001)及AUC实质/流入比变化(ρ=0.31,p=0.0018)显著相关。作者认为2D-PA量化BPA前后肺灌注可行,有潜力改善BPA监测。
要点
- 2D-PA通过DSA后处理量化BPA前后肺实质灌注变化是可行的。
- BPA后TTP实质/流入比缩短10%,PD实质/流入比增加46%,AUC实质/流入比增加36%。
- 肺血流分级评分变化与PD实质/流入比变化(ρ=0.48)及AUC实质/流入比变化(ρ=0.31)显著相关。
核心结论
- 使用2D-PA量化BPA前后肺灌注是可行的,并有潜力改善BPA的监测。
研究设计与样本
- 纳入16例慢性血栓栓塞性肺动脉高压患者的30次连续介入、共99个治疗肺动脉段;对BPA前后采集的DSA图像进行后处理,在治疗的肺动脉内放置参考ROI、在肺实质远端放置目标ROI,计算TTP、PD、AUC及参考ROI与目标ROI的比值,并将2D-PA参数相对变化与肺血流分级评分变化做相关分析。
关键影像表现/征象
- BPA后肺血流分级评分改善(p<0.0001)。
- BPA后TTP实质/流入比缩短10%(p=0.0002)。
- BPA后PD实质/流入比增加46%(p<0.0001)。
- BPA后AUC实质/流入比增加36%(p<0.0001)。
诊断标准与关键数值
- 2D-PA参数包括TTP、PD、AUC及参考ROI与目标ROI的比值(TTP实质/TTP流入、PD实质/PD流入、AUC实质/AUC流入)。
- 肺血流分级评分变化与PD实质/流入比变化显著相关(ρ=0.48,p<0.0001)。
- 肺血流分级评分变化与AUC实质/流入比变化显著相关(ρ=0.31,p=0.0018)。
临床应用与阅片要点
- 可在BPA前后对DSA图像做2D-PA后处理,在治疗的肺动脉内放置参考ROI、在肺实质远端放置目标ROI,计算TTP、PD、AUC及其比值。
- 2D-PA可客观评估肺实质灌注变化,作者认为其有潜力改善BPA监测。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the feasibility of 2D-perfusion angiography (2D-PA) in order to quantify perfusion changes of the lung parenchyma pre- and post-balloon pulmonary angioplasty (BPA).
METHODS: Thirty consecutive interventions in 16 patients with 99 treated pulmonary artery segments were included. To quantify changes in pulmonary blood flow using 2D-PA, the acquired digital subtraction angiographies (DSA) pre- and post-BPA were post-processed. A reference ROI in the treated pulmonary artery and a distal target ROI in the lung parenchyma were placed in corresponding areas on DSA pre- and post-BPA. Time to peak (TTP), peak density (PD) and area under the curve (AUC) were assessed. The ratios reference ROI to target ROI (TTPparenchyma/TTPinflow; PDparenchyma/PDinflow; AUCparenchyma/AUCinflow) were calculated. Relative differences of the 2D-PA parameters were correlated to changes in the pulmonary-flow-grade-score.
RESULTS: The pulmonary-flow-grade-score improved after BPA (p<0.0001). Likewise, the ratio TTPparenchyma/TTPinflow shortened by 10% (p=0.0002), the PDparenchyma/PDinflow increased by 46% (p<0.0001) and the AUCparenchyma/AUCinflow increased by 36% (p<0.0001). A significant correlation between changes in the pulmonary-flow-grade-score and changes in PDparenchyma/PDinflow (ρ=0.48, p<0.0001) and AUCparenchyma/AUCinflow (ρ=0.31, p=0.0018) was observed.
CONCLUSION: Quantification of pulmonary perfusion pre- and post-BPA using 2D-PA is feasible and has the potential to improve monitoring of BPA.
KEY POINTS: • Quantification of BPA results by use of 2D-PA is feasible. • 2D-PA allows objective assessment of changes in lung parenchymal perfusion. • 2D-PA has the potential to optimize BPA.
引用
- Maschke SK, Renne J, Werncke T, et al. Chronic thromboembolic pulmonary hypertension: Evaluation of 2D-perfusion angiography in patients who undergo balloon pulmonary angioplasty. Eur Radiol. 2017. PMID: 28361177. doi:10.1007/s00330-017-4806-z