数字断层合成与计算机断层扫描在SOS筛查项目中肺结节检出效果的比较
在SOS前瞻性肺癌筛查项目中,132例因数字断层合成发现非钙化结节(直径大于5 mm和/或多发结节)而接受CT检查的受试者中,两位专家放射科医师比较了数字断层合成与CT对肺结节的检出。数字断层合成检出208个结节、CT检出179个;CT确认了数字断层合成所见189个实性、部分实性和磨玻璃结节中的140个(74%),但发现4个数字断层合成未检出的结节。按5点LUNG-RADS量表两者一致率为62%,按可疑/不可疑二分类量表一致率升至86%;CT与数字断层合成的ROC曲线下面积分别为0.89(95%CI 0.83-0.94)和0.80(95%CI 0.72-0.89)。
要点
- 数字断层合成检出208个结节,CT检出179个,CT为参考标准。
- 数字断层合成所见189个实性、部分实性和磨玻璃结节中,CT确认140个(74%)。
- CT发现4个数字断层合成未检出的结节。
核心结论
- 在数字断层合成与CT中使用共同分类有助于比较两种技术;数字断层合成检出并正确分类了CT所见结节的74%,但漏掉了CT识别的4个结节;按二分类LUNG-RADS量表,两者一致率升至86%。
研究设计与样本
- SOS前瞻性筛查研究;1843名入组受试者中132例因数字断层合成发现直径大于5 mm的非钙化结节和/或多发结节而接受CT检查;两位专家放射科医师审阅检查,按影像表现和尺寸对结节分类,以CT为参考标准应用LUNG-RADS分类比较受试者工作特征曲线。
关键影像表现/征象
- 数字断层合成检出208个结节,其中189个(91%)为实性、部分实性或磨玻璃结节。
- CT检出179个结节,并确认了数字断层合成所见189个结节中的140个(74%)。
- CT发现4个数字断层合成未检出的结节。
- 按5点LUNG-RADS量表,数字断层合成与CT的一致率为62%;按可疑/不可疑二分类量表,一致率为86%。
诊断标准与关键数值
- 以CT为参考标准,CT的ROC曲线下面积为0.89(95%CI 0.83-0.94),数字断层合成的ROC曲线下面积为0.80(95%CI 0.72-0.89)。
- 结节分类基于影像表现和尺寸,并应用LUNG-RADS分类。
临床应用与阅片要点
- 在数字断层合成与CT中使用共同分类(LUNG-RADS)有助于比较两种技术对结节的检出。
- 数字断层合成检出并正确分类了CT所见结节的74%,但漏掉了CT识别的4个结节。
- 按二分类LUNG-RADS量表评估时,数字断层合成与CT的一致率为86%。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the lung nodules' detection of digital tomosynthesis (DTS) and computed tomography (CT) in the context of the SOS (Studio OSservazionale) prospective screening program for lung cancer detection.
MATERIALS AND METHODS: One hundred and thirty-two of the 1843 subjects enrolled in the SOS study underwent CT because non-calcified nodules with diameters larger than 5 mm and/or multiple nodules were present in DTS. Two expert radiologists reviewed the exams classifying the nodules based on their radiological appearance and their dimension. LUNG-RADS classification was applied to compare receiver operator characteristics curve between CT and DTS with respect to final diagnosis. CT was used as gold standard.
RESULTS: DTS and CT detected 208 and 179 nodules in the 132 subjects, respectively. Of these 208 nodules, 189 (91%) were solid, partially solid, and ground glass opacity. CT confirmed 140/189 (74%) of these nodules but found 4 nodules that were not detected by DTS. DTS and CT were concordant in 62% of the cases applying the 5-point LUNG-RADS scale. The concordance rose to 86% on a suspicious/non-suspicious binary scale. The areas under the curve in receiver operator characteristics were 0.89 (95% CI 0.83-0.94) and 0.80 (95% CI 0.72-0.89) for CT and DTS, respectively. The mean effective dose was 0.09 ± 0.04 mSv for DTS and 4.90 ± 1.20 mSv for CT.
CONCLUSIONS: The use of a common classification for nodule detection in DTS and CT helps in comparing the two technologies. DTS detected and correctly classified 74% of the nodules seen by CT but lost 4 nodules identified by CT. Concordance between DTS and CT rose to 86% of the nodules when considering LUNG-RADS on a binary scale.
引用
- Grosso M, Priotto R, Ghirardo D, et al. Comparison of digital tomosynthesis and computed tomography for lung nodule detection in SOS screening program. Radiol Med. 2017. PMID: 28429205. doi:10.1007/s11547-017-0765-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。