文献速递头颈CT

头颈部肿瘤分期的CT检查:双源双能量与低千伏单能量采集的对比

Computed Tomography of the Head and Neck Region for Tumor Staging-Comparison of Dual-Source, Dual-Energy and Low-Kilovolt, Single-Energy Acquisitions.
PubMed 文献 · Invest Radiol · 2017-01-01

本研究在49例头颈部恶性肿瘤患者中,个体内比较双源双能量CT不同虚拟单能重建与70kV单能量CT的图像质量。40keV虚拟单能图像在血管和肿瘤对比噪声比及主观图像质量上最高,但与60keV、加权平均图像及70kV单能量图像的主观差异无统计学意义;高keV虚拟单能可减少金属伪影,但严重牙科硬件时诊断价值有限。

要点

  • 40keV虚拟单能图像对头颈部肿瘤轮廓显示的整体图像质量最高。
  • 60keV虚拟单能、加权平均图像与70kV单能量CT的客观图像质量相当。
  • 严重牙科硬件伪影时可采用对准颌骨的改良投影,70kV单能量CT可作为替代方案。

核心结论

  • 40keV虚拟单能重建在头颈部肿瘤显示中提供最高整体图像质量,但70kV单能量检查可作为替代方案,严重牙科硬件伪影时推荐采用对准颌骨的改良投影。

研究设计与样本

  • 对49例组织学证实头颈部恶性疾病患者行第三代双源双能量CT,重建加权平均图像及40、60、120、190keV虚拟单能图像,并另以70kV管电压、匹配辐射剂量的单能量协议行对准颌骨、覆盖口腔的第二次扫描。

诊断标准与关键数值

  • 血管和肿瘤衰减的对比噪声比在40keV虚拟单能图像中最高(所有P<0.05);60keV虚拟单能、加权平均图像与70kV单能量检查的客观结果相当。

临床应用与阅片要点

  • 作者建议严重牙科硬件伪影时采用对准颌骨的改良投影;高keV虚拟单能图像可减少金属伪影,但因严重牙科硬件时信息不足而诊断价值有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of this study was to intra-individually compare the image quality obtained by dual-source, dual-energy (DSDE) computed tomography (CT) examinations and different virtual monoenergetic reconstructions to a low single-energy (SE) scan.

MATERIALS AND METHODS: Third-generation DSDE-CT was performed in 49 patients with histologically proven malignant disease of the head and neck region. Weighted average images (WAIs) and virtual monoenergetic images (VMIs) for low (40 and 60 keV) and high (120 and 190 keV) energies were reconstructed. A second scan aligned to the jaw, covering the oral cavity, was performed for every patient to reduce artifacts caused by dental hardware using a SE-CT protocol with 70-kV tube voltages and matching radiation dose settings. Objective image quality was evaluated by calculating contrast-to-noise ratios. Subjective image quality was evaluated by experienced radiologists.

RESULTS: Highest contrast-to-noise ratios for vessel and tumor attenuation were obtained in 40-keV VMI (all P < 0.05). Comparable objective results were found in 60-keV VMI, WAI, and the 70-kV SE examinations. Overall subjective image quality was also highest for 40-keV, but differences to 60-keV VMI, WAI, and 70-kV SE were nonsignificant (all P > 0.05). High kiloelectron volt VMIs reduce metal artifacts with only limited diagnostic impact because of insufficiency in case of severe dental hardware. CTDIvol did not differ significantly between both examination protocols (DSDE: 18.6 mGy; 70-kV SE: 19.4 mGy; P = 0.10).

CONCLUSIONS: High overall image quality for tumor delineation in head and neck imaging were obtained with 40-keV VMI. However, 70-kV SE examinations are an alternative and modified projections aligned to the jaw are recommended in case of severe artifacts caused by dental hardware.

来源:Invest Radiol,查看原文。版权归原作者所有。