使用低剖面可视化腔内支撑装置辅助弹簧圈栓塞起源于小型(<2.5 mm)脑内血管的动脉瘤的初步经验
这项单中心回顾性研究纳入2014年10月至2016年4月间22例使用LVIS支架治疗载瘤动脉直径小于2.5 mm的囊状动脉瘤患者,支架置入成功率100%,1例(4.5%)出现手术相关并发症,平均8.3个月随访完全闭塞率为81.8%,无再通。作者认为LVIS支架在小血管中置入中期可行、安全、有效,但需要更大样本长期随访验证。
要点
- LVIS支架在直径1.7–2.4 mm(平均2.1 mm)的小载瘤动脉中置入成功率为100%。
- 术后即刻完全闭塞8例(36.4%),平均8.3个月随访完全闭塞18例(81.8%)。
- 随访中未见靶动脉瘤再通,1例出现无症状性支架内狭窄。
核心结论
- 作者初步结论认为LVIS支架在小血管中置入中期可行、安全、有效,但需要更大样本长期随访验证。
研究设计与样本
- 单中心回顾性研究,纳入2014年10月至2016年4月间使用LVIS支架治疗载瘤动脉直径小于2.5 mm的囊状动脉瘤患者22例(5例破裂、17例未破裂),分析手术相关并发症、血管造影结果、临床结局和中期随访数据。
关键影像表现/征象
- 动脉瘤多位于前循环(90.9%)。
- 支架置入的载瘤动脉直径为1.7–2.4 mm(平均2.1 mm),置入成功率为100%。
- 术后即刻血管造影显示完全闭塞8例(36.4%)、瘤颈残留8例(36.4%)、瘤体残留6例(27.3%)。
- 平均8.3个月随访血管造影显示完全闭塞18例(81.8%)、瘤颈残留3例(13.6%)、瘤囊残留1例(4.5%)。
- 随访中未见靶动脉瘤再通,1例出现无症状性支架内狭窄。
局限性
- 作者指出需要更大样本长期随访研究来验证其初步结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: The Low-Profile Visualized Intraluminal Support (LVIS) stent is a new device recently introduced for the treatment of wide-neck intracranial aneurysms. This single-center study presents the authors' preliminary experience using the LVIS stent to treat saccular aneurysms with parent arteries smaller than 2.5 mm.
MATERIALS AND METHODS: Aneurysms with a LVIS stent used in a small parent vessel (<2.5 mm in diameter) between October 2014 and April 2016 were included. Procedure-related complications, angiographic results, clinical outcomes, and midterm follow-up data were analyzed retrospectively.
RESULTS: A total of 22 patients was studied, including 5 ruptured and 17 unruptured aneurysms. Most of the aneurysms were located in the anterior circulation (90.9%). Stent placement in the parent arteries measuring 1.7-2.4 mm in diameter (mean, 2.1 mm) was successful in 100% of cases. Procedure-related complication developed in 1 patient (4.5%) who presented with aneurysm rupture. No permanent morbidity and mortality occurred. Immediate angiographic outcome showed complete occlusion in 8 aneurysms (36.4%), neck residual in 8 (36.4%), and residual aneurysm in 6 (27.3%). All patients underwent angiographic follow-up at a mean of 8.3 months, which revealed complete occlusion in 18 (81.8%) patients, neck remnant in 3 (13.6%), and residual sac in 1 (4.5%). No recanalization of the target aneurysm was observed. There was 1 case with asymptomatic in-stent stenosis.
CONCLUSIONS: Our preliminary results show that the deployment of LVIS stents in small vessels is feasible, safe, and effective in the midterm. Larger studies with long-term follow-up are needed to validate our promising results.
引用
- Wang CC, Li W, Feng ZZ, et al. Preliminary Experience with Stent-Assisted Coiling of Aneurysms Arising from Small (<2.5 mm) Cerebral Vessels Using The Low-Profile Visualized Intraluminal Support Device. AJNR Am J Neuroradiol. 2017. PMID: 28385886. doi:10.3174/ajnr.A5145
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。