应用颅外颈内动脉多普勒超声评估脑动态自动调节功能

Dynamic Cerebral Autoregulation Assessment Using Extracranial Internal Carotid Artery Doppler Ultrasonography.
PubMed 文献 · Ultrasound Med Biol · 2017-04-12

研究纳入32例卒中患者和59名对照,同步测量颅外颈内动脉与大脑中动脉的动态脑自动调节指标,发现平均流速相关指数和相位偏移在两者间无显著差异,但极低频和低频增益在颈内动脉显著低于大脑中动脉,结论为颅外颈内动脉评估动态脑自动调节与大脑中动脉同样有效,但结果不可互换。

要点

  • 颅外颈内动脉与大脑中动脉的平均流速相关指数和相位偏移无显著差异。
  • 极低频和低频增益在颈内动脉显著低于大脑中动脉(平均差值分别为-0.13和-0.10)。
  • 颅外颈内动脉与大脑中动脉的动态脑自动调节指标不可互换。

核心结论

  • 颅外颈内动脉评估的动态脑自动调节与大脑中动脉同样有效,但两者结果不可互换。

研究设计与样本

  • 研究纳入32例卒中患者和59名对照,同步进行颅外颈内动脉和大脑中动脉的平均流速相关指数及基于自发血压波动的传递函数分析。

诊断标准与关键数值

  • 平均流速相关指数和相位偏移的平均值在颈内动脉与大脑中动脉间无显著差异(平均差值:平均流速相关指数=0.01;极低频相位偏移=0.7°,低频=3.3°,高频=4.5°);极低频和低频增益在颈内动脉显著低于大脑中动脉(平均差值:极低频增益=-0.13,低频增益=-0.10);平均流速相关指数的组内相关系数为0.76,极低频相位偏移的组内相关系数为0.72;卒中诊断的受试者工作特征曲线下面积在各动态脑自动调节指标间无差异。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Transcranial Doppler ultrasonography of the middle cerebral artery (MCA) is frequently used to assess dynamic cerebral autoregulation (dCA); however, this is difficult in patients with poor temporal bone windows. In the study described here, we investigated the agreement and sensitivity of dCA indices determined from the extracranial internal carotid artery (ICA) and those determined from the MCA. Measurements for 32 stroke patients and 59 controls were analyzed. Measurement of the mean flow correlation index (Mx) and transfer function analysis based on spontaneous blood pressure fluctuation were simultaneously performed for the extracranial ICA and MCA. The mean values of Mx and phase shift did not significantly differ between the ICA and MCA (mean difference: Mx = 0.01; phase shift of very low frequency [VLF] = 0.7°, low frequency [LF] = 3.3° and high frequency = 4.5°), but the gains in VLF and LF in the ICA were significantly lower than those in the MCA (mean difference: gain of VLF = -0.13, gain of LF = -0.10). The intra-class correlation coefficient between the dCA indices of the ICA and MCA was favorable in Mx (0.76) and the phase shift of VLF (0.72). The area under the receiver operating characteristic curve for stroke diagnosis did not differ among the dCA indices. We conclude that dCA assessed from the ICA is as effective as that from the MCA, but the results are not interchangeable.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Chi NF, Ku HL, Wang CY, et al. Dynamic Cerebral Autoregulation Assessment Using Extracranial Internal Carotid Artery Doppler Ultrasonography. Ultrasound Med Biol. 2017. PMID: 28411965. doi:10.1016/j.ultrasmedbio.2017.02.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。