诊断超声诱导微泡空化对急性颈动脉血栓栓塞的溶栓效应
在38条猪颈动脉上制作急性血栓性闭塞模型,分别给予低机械指数单独成像、稳定空化或惯性空化脉冲治疗30分钟,经磁共振血管造影评估下游血管再通;至少轻度再通在稳定空化组为64%,高于惯性空化组的33%和低机械指数单独组的29%(P=0.001)。
要点
- 稳定空化脉冲组至少轻度再通(TICI 2a或以上)为64%,高于惯性空化组33%和低机械指数单独组29%(P=0.001)。
- 中度或完全再通(TICI 2b或以上)稳定空化组为39%,高于惯性空化组10%和低机械指数单独组21%(P=0.001)。
- 溶栓效应仅在稳定空化脉冲时出现,更高机械指数的惯性空化脉冲出现效应逆转。
核心结论
- 在商用微泡输注期间给予高机械指数20微秒脉冲可再通急性血栓闭塞的颈动脉并恢复下游血流,且无需抗凝药;但该效应仅见于稳定空化诱导脉冲,在更高机械指数时观察到溶栓效应的矛盾性逆转。
研究设计与样本
- 在38条猪颈动脉远端颅外段建立球囊过度损伤后,于损伤近端中段用部分球囊充盈造成70%至80%狭窄,并在球囊导管远端注入新鲜自体动脉血栓建立急性血栓性闭塞。血管造影证实闭塞后,分别给予诊断性低机械指数单独成像(0.2 MI;Philips S5-1,经组织模仿体模施加)、间歇诊断性高机械指数稳定空化诱导脉冲(0.8 MI;20微秒脉冲宽度)或惯性空化脉冲(1.2 MI;20微秒脉冲宽度)治疗,所有治疗时间均为30分钟,治疗期间静脉输注超声造影剂(2% Definity;Lantheus Medical)。以磁共振三维时间飞跃法和相位对比血管造影评估颈动脉闭塞下游4支颅内和颅外血管(耳廓、咽升、颊、上颌)的血管造影再通,所有磁共振图像由独立神经放射科医师采用脑梗死溶栓(TICI)评分系统判读。
诊断标准与关键数值
- 相位对比血管造影显示,至少轻度再通(TICI 2a或以上)在稳定空化脉冲治疗的下游血管为64%,惯性空化治疗为33%,低机械指数单独治疗为29%(P=0.001);中度或完全再通(TICI 2b或以上)在稳定空化治疗血管为39%,惯性空化治疗为10%,低机械指数单独治疗为21%(P=0.001)。
临床应用与阅片要点
- 作者认为,商用微泡输注期间的高机械指数20微秒脉冲可用于再通急性血栓闭塞的颈动脉并恢复下游血流;诊断超声诱导的稳定空化可能成为溶解颈动脉血栓并预防血栓栓塞的非手术方法。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Acute ischemic stroke is often due to thromboembolism forming over ruptured atherosclerotic plaque in the carotid artery (CA). The presence of intraluminal CA thrombus is associated with a high risk of thromboembolic cerebral ischemic events. The cavitation induced by diagnostic ultrasound high mechanical index (MI) impulses applied locally during a commercially available intravenous microbubble infusion has dissolved intravascular thrombi, especially when using longer pulse durations. The beneficial effects of this in acute carotid thromboembolism is not known.
MATERIALS AND METHODS: An oversized balloon injury was created in the distal extracranial common CA of 38 porcine carotid arteries. After this, a 70% to 80% stenosis was created in the mid common CA proximal to the injury site using partial balloon inflation. Acute thrombotic CA occlusions were created just distal to the balloon catheter by injecting fresh autologous arterial thrombi. After angiographic documentation of occlusion, the common carotid thrombosis was treated with either diagnostic low MI imaging alone (0.2 MI; Philips S5-1) applied through a tissue mimicking phantom (TMP) or intermittent diagnostic high MI stable cavitation (SC)-inducing impulses with a longer pulse duration (0.8 MI; 20 microseconds' pulse duration) or inertial cavitation (IC) impulses (1.2 MI; 20 microseconds' pulse duration). All treatment times were for 30 minutes. Intravenous ultrasound contrast (2% Definity; Lantheus Medical) was infused during the treatment period. Angiographic recanalization in 4 intracranial and extracranial vessels downstream from the CA occlusion (auricular, ascending pharyngeal, buccinator, and maxillary) was assessed with both magnetic resonance 3-dimensional time-of-flight and phase contrast angiography. All magnetic resonance images were interpreted by an independent neuroradiologist using the thrombolysis in cerebral infarction (TICI) scoring system.
RESULTS: By phase contrast angiography, at least mild recanalization (TICI 2a or higher) was seen in 64% of downstream vessels treated with SC impulses compared with 33% of IC treated and 29% of low MI alone treated downstream vessels (P = 0.001), whereas moderate or complete recanalization (TICI 2b or higher) was seen in 39% of SC treated vessels compared with 10% IC treated and 21% of low MI alone treated vessels (P = 0.001).
CONCLUSIONS: High MI 20-microsecond pulse duration impulses during a commercial microbubble infusion can be used to recanalize acutely thrombosed carotid arteries and restore downstream flow without anticoagulants. However, this effect is only seen with SC-inducing impulses and not at higher mechanical indices, when a paradoxical reversal of the thrombolytic effect is observed. Diagnostic ultrasound-induced SC can be a nonsurgical method of dissolving CA thrombi and preventing thromboembolization.
引用
- Porter TR, Xie F, Lof J, et al. The Thrombolytic Effect of Diagnostic Ultrasound-Induced Microbubble Cavitation in Acute Carotid Thromboembolism. Invest Radiol. 2017. PMID: 28383307. doi:10.1097/RLI.0000000000000369
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。