文献速递神经技术与安全US

急诊医学医师测量超声视神经鞘直径的评定者间信度

Inter-rater Reliability of Sonographic Optic Nerve Sheath Diameter Measurements by Emergency Medicine Physicians.
PubMed 文献 · J Ultrasound Med · 2017-04-03

研究比较超声 fellowship 培训的急诊医学主治医师与住院医师测量视神经鞘直径(ONSD)的一致性。住院医师组 ICC 为 0.50(95%CI 0.25-0.89),超声 fellowship 培训主治医师组 ICC 为 0.73(95%CI 0.44-0.96),两组各图像中位 ONSD 测量值无显著差异。作者结论认为即便在熟练者手中,超声 ONSD 测量作为颅内压升高的筛查工具可能不如既往文献所述可靠。

要点

  • 住院医师测量 ONSD 的评定者间 ICC 为 0.50,低于超声 fellowship 培训主治医师的 0.73。
  • 超声培训主治医师组 ICC 95%CI 下限为 0.44,提示组内一致性变异可能较宽。
  • 各图像中位 ONSD 测量值在住院医师与超声培训主治医师间无显著差异。

核心结论

  • 住院医师与超声 fellowship 培训急诊医学医师测量 ONSD 均显示良好评定者间信度,但超声培训医师组一致性变异可能宽达 0.44,提示超声 ONSD 测量作为颅内压升高筛查工具的可靠性可能不如既往文献所述。

研究设计与样本

  • 研究纳入来自多家机构的 10 名超声 fellowship 培训急诊医学主治医师和单一住院医师培训项目的 51 名急诊医学住院医师,对 5 幅包含球后视神经的成人眼部静态超声图像使用计算机标尺测量 ONSD。

诊断标准与关键数值

  • 住院医师组 ONSD 测量评定者间 ICC 为 0.50(95%CI 0.25-0.89),超声 fellowship 培训主治医师组 ICC 为 0.73(95%CI 0.44-0.96)。

局限性

  • 超声 fellowship 培训主治医师组 ICC 的 95%CI 下限为 0.44,作者据此指出即便在熟练者手中 ONSD 测量作为颅内压升高筛查工具的可靠性可能不如既往文献所述。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare the degree of agreement of sonographic optic nerve sheath diameter (ONSD) measurements by ultrasound fellowship-trained and resident emergency medicine (EM) physicians.

METHODS: Ten ultrasound fellowship-trained EM attending physicians from multiple institutions and 51 resident EM physicians at a single residency were enrolled to measure the ONSD using a computerized ruler on five separate still-frame sonograms of adult eyes that included the retrobulbar optic nerve. Descriptive and bivariate statistics for each ultrasound image were calculated to compare median ONSD measurements among groups. Intraclass correlation coefficients (ICCs) were calculated to estimate the inter-rater reliability.

RESULTS: Although the median ONSD measurement of each image did not significantly differ between resident and ultrasound fellowship-trained EM physicians, we found greater variation in agreement of ONSD measurements by resident EM physicians (ICC 0.50; 95% confidence interval 0.25-0.89) than ultrasound fellowship-trained EM physicians (ICC 0.73; 95% confidence interval 0.44-0.96).

CONCLUSIONS: Although both resident and ultrasound fellowship-trained EM physicians showed good inter-rater reliability of ONSD measurements, variation in agreement among ultrasound fellowship-trained EM physicians may be as wide as 0.44, suggesting that even in skilled hands, ultrasound measurement of the ONSD may not be as dependable a screening tool for elevated intracranial pressure as previously suggested in the literature.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Oberfoell S, Murphy D, French A, et al. Inter-rater Reliability of Sonographic Optic Nerve Sheath Diameter Measurements by Emergency Medicine Physicians. J Ultrasound Med. 2017. PMID: 28370143. doi:10.7863/ultra.16.05055

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。