颅内动脉狭窄闭塞:二维空间选择性射频激发脉冲MR成像诊断
本回顾性研究纳入88例患者,比较二维空间选择性射频激发脉冲MR成像(zoomed MR成像)与全视野MR成像对颅内动脉狭窄闭塞的诊断。两种方法诊断一致率为93%(164/176处病变),一致率差异为2.84%(单侧95%CI:-0.49%,6.17%),诊断相关参数无显著差异(均P>.05)。结论认为zoomed MR成像诊断颅内动脉狭窄闭塞可靠。
要点
- zoomed MR成像与全视野MR成像诊断颅内动脉狭窄闭塞的一致率为93%(164/176处病变)。
- 两种方法诊断相关参数无显著差异(均P>.05),组内相关系数和κ值均≥0.61。
- 全视野MR成像的平扫信噪比和图像质量评分优于zoomed MR成像(均P<.05)。
核心结论
- zoomed MR成像诊断颅内动脉狭窄闭塞与全视野MR成像相比是可靠的方法。
研究设计与样本
- 回顾性研究,纳入2014年12月至2015年8月间88例在先前管腔评估后需进一步评估颅内动脉狭窄闭塞的患者,均行全视野MR成像和zoomed MR成像。
- 由两名神经放射学家独立基于临床信息和MR影像特征诊断疾病(动脉粥样硬化、夹层、烟雾病、血管炎、未确定诊断和无血管病理状态),并评估诊断相关参数和图像质量参数。
- 采用配对t检验和McNemar检验比较参数测量值,以非劣效性检验中一致率差异的95%置信区间上限小于10%作为方法间可靠性标准。
诊断标准与关键数值
- 全视野MR成像与zoomed MR成像诊断疾病的合并一致率为93%(164/176处病变)。
- 一致率差异为2.84%(单侧95%CI:-0.49%,6.17%)。
- 诊断相关参数(直径、长度、偏心指数、偏心度、信号强度比、血管壁出血和病变总数)在两种方法间无显著差异(均P>.05),组内相关系数和κ值均≥0.61。
- 全视野MR成像的平扫信噪比和图像质量评分优于zoomed MR成像(均P<.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To determine whether magnetic resonance (MR) imaging by using two-dimensional spatially selective radiofrequency (RF) excitation pulses (zoomed MR imaging) is a reliable method for the diagnosis of intracranial artery steno-occlusion compared with full-field-of-view (FOV) MR imaging. Materials and Methods The institutional review board approved this retrospective study and informed consent was waived. From December 2014 to August 2015, 88 patients who underwent both full-FOV MR imaging and zoomed MR imaging for further evaluation of intracranial artery steno-occlusion at prior luminal evaluation were included. Two neuroradiologists independently diagnosed the diseases (atherosclerosis, dissection, moyamoya disease, vasculitis, undetermined diagnosis, and no vascular pathologic condition) based on both clinical information and MR imaging features and assessed diagnosis-related parameters (diameter, length, eccentricity index, eccentricity, signal intensity ratio, vessel wall hemorrhage, and the total number of lesions), as well as image quality parameters (signal-to-noise ratio and image quality scale) with full-FOV MR imaging and zoomed MR imaging. Parametric measurements were compared between full-FOV MR imaging and zoomed MR imaging by using paired t test and McNemar test. The criterion for intermethod reliability was that the upper limit of the 95% confidence interval (CI) in the difference of agreement was less than 10% based on a noninferiority test. Results The pooled agreement for diagnosing the disease between full-FOV MR imaging and zoomed MR imaging was 93% (164 of 176 lesions). The difference of agreement was 2.84% (one-sided 95% CI: -0.49%, 6.17%). The diagnosis-related parameters were not significantly different between both methods (all P > .05), with good to excellent agreement (both intraclass correlation coefficient and κ value ≥0.61). However, full-FOV MR imaging had better image quality parameters than zoomed MR imaging, including precontrast signal-to-noise ratio and image quality scale (both P < .05). Conclusion Zoomed MR imaging is a reliable method for the diagnosis of intracranial artery steno-occlusion compared with full-FOV MR imaging. © RSNA, 2017 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on May 2, 2017.