脑白质高信号进展与相关超声指数
研究纳入450例接受经颅多普勒超声和MRI检查、并在34-45个月内复查影像的个体,评估大脑中动脉M1段阻力指数(RI)与白质高信号(WMH)进展的关系。结果显示MRIR与WMH体积变化线性相关(r=0.328,P<.001),MRIR≥1.000与WMH体积增加更多相关(P<.001)。结论认为MRIR可能反映穿支动脉搏动,并与WMH进展独立相关。
要点
- MRIR定义为远端RI除以近端RI,基于TCD评估近端M1与远端M1间距约20mm。
- MRIR与WMH体积变化线性相关(r=0.328,P<.001),MRIR≥1.000与WMH体积增加更多相关。
- 基线WMH体积(r=0.433,P<.001)和平均MCA搏动指数(r=0.275,P=.037)也与WMH体积变化相关。
核心结论
- MRIR可能反映穿支动脉搏动,并与WMH进展独立相关。
研究设计与样本
- 研究经首尔大学医院机构审查委员会批准,纳入450例初始接受经颅多普勒超声和MRI检查、随访影像在34-45个月内完成、且颈内动脉或大脑中动脉狭窄不足30%或无陈旧性腔隙性脑梗死以外卒中史的个体;MRIR定义为远端RI除以近端RI,基于TCD评估近端M1与远端M1间距约20mm;WMH进展通过随访WMH体积减去基线WMH体积定量评估。
诊断标准与关键数值
- 基线平均MRIR为0.974±0.045,平均WMH体积为9.66 mL±14.54;平均38.3个月±3.4后,WMH体积变化为4.06 mL±7.35;MRIR≥1.000与WMH体积增加更多相关(P<.001)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To evaluate the relationship between penetrating arterial pulsation and the progression of white matter hyperintensities (WMHs) by using the sonographic resistance index (RI) along the M1 segment of the middle cerebral artery (MCA). Materials and Methods The study design was approved by the institutional review board of Seoul National University Hospital. The study included 450 individuals who had undergone initial transcranial Doppler (TCD) sonography and magnetic resonance imaging, with follow-up imaging performed within 34-45 months, and who had no stenosis of 30% or more in the internal carotid artery or MCA or a history of stroke other than an old lacunar infarction. MRIR was defined as distal RI divided by proximal RI, where the distance between proximal MI and distal M1 was approximately 20 mm based on TCD evaluation. WMH progression was quantitatively evaluated by subtracting WMH volume at baseline from WMH volume at follow-up. Results At baseline, mean MRIR was 0.974 ± 0.045 (standard deviation), and mean WMH volume was 9.66 mL ± 14.54. After a mean of 38.3 months ± 3.4, the WMH volume change was 4.06 mL ± 7.35. WMH volume change was linearly associated with MRIR (r = 0.328, P < .001), along with the baseline WMH volume (r = 0.433, P < .001) and mean MCA pulsatility index (r = 0.275, P = .037). MRIR values greater than or equal to 1.000 were associated with a greater increase in WMH volume (P < .001). Conclusion MRIR might reflect the pulsation of penetrating arteries and is independently associated with WMH progression. © RSNA, 2017 Online supplemental material is available for this article.
引用
- Lee WJ, Jung KH, Ryu YJ, et al. Progression of Cerebral White Matter Hyperintensities and the Associated Sonographic Index. Radiology. 2017. PMID: 28394756. doi:10.1148/radiol.2017162064
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。