仅用平扫双能谱CT鉴别肾盂旁囊肿与非结石性肾积水的前瞻性初步研究
本研究回顾性纳入28例肾盂旁囊肿和24例非结石性肾积水(HNC)患者,评估仅基于平扫双能谱CT定量参数(70-keV单能图像CT值、有效原子序数、碘浓度、水浓度及能谱曲线斜率)的鉴别价值。结果显示70-keV CT值、有效原子序数和碘浓度在两组间差异有统计学意义,联合特异度达92.9%,作者认为平扫双能谱CT参数可能用于鉴别肾盂旁囊肿与HNC。
要点
- 平扫双能谱CT的70-keV CT值、有效原子序数和碘浓度在肾盂旁囊肿与HNC间差异有统计学意义。
- 各参数单独鉴别敏感度64.9%–91.9%、特异度40.0%–73.3%,联合特异度达92.9%。
- 能谱曲线斜率在两组间无统计学差异,不宜单独用于鉴别。
核心结论
- 平扫双能谱CT成像获得的定量参数可能用于鉴别肾盂旁囊肿与非结石性肾积水,从而可能使无症状患者避免增强CT或CT尿路造影,减少电离辐射剂量和对比剂剂量。
研究设计与样本
- 回顾性研究,经机构审查委员会批准,纳入28例肾盂旁囊肿和24例非结石性肾积水患者,均行标准平扫及多期增强双能谱CT成像,以增强扫描作为参考标准。
关键影像表现/征象
- 肾盂旁囊肿与HNC在70-keV单能图像CT值、有效原子序数和碘浓度上差异有统计学意义(均p<0.05)。
- 能谱曲线斜率在两组间无统计学差异(p>0.05)。
诊断标准与关键数值
- 70-keV CT值鉴别肾盂旁囊肿与HNC的敏感度89.2%、特异度73.3%、准确率82.1%。
- 有效原子序数鉴别的敏感度86.5%、特异度43.3%、准确率67.2%。
- 碘浓度鉴别的敏感度91.9%、特异度40.0%、准确率68.7%。
- 水浓度鉴别的敏感度64.9%、特异度73.3%、准确率83.6%。
- 上述参数联合鉴别特异度为92.9%。
临床应用与阅片要点
- 作者认为,平扫双能谱CT扫描可能用于筛查无症状的肾盂旁囊肿患者,从而避免增强CT或CT尿路造影检查,以减少电离辐射剂量和对比剂剂量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the value of using the quantitative parameters from only the pre-contrast dual-energy spectral CT imaging for distinguishing between parapelvic cyst and hydronephrosis with non-calculous (HNC).
METHODS: This retrospective study was approved by the institutional review board. 28 patients with parapelvic cyst and 24 patients with HNC who underwent standard pre-contrast and multiphase contrast-enhanced dual-energy spectral CT imaging were retrospectively identified. The parapelvic cyst and HNC were identified using the contrast-enhanced scans, and their CT number in the 70-keV monochromatic images, effective atomic number (Zeff), iodine concentration (IC) and water concentration in the pre-contrast images were measured. The slope of the spectral curve (λ) was calculated. The difference in the measurements between parapelvic cyst and HNC was statistically analyzed using SPSS® v. 19.0 (IBM Corp., New York, NY; formerly SPSS Inc., Chicago, IL) statistical software. Receiver-operating characteristic analysis was performed to assess the diagnostic performance.
RESULTS: The CT numbers in the 70-keV images, Zeff and IC values were statistically different between parapelvic cyst and HNC (all p < 0.05). The sensitivity, specificity and accuracy of these parameters for distinguishing between parapelvic cyst and HNC were 89.2%, 73.3% and 82.1%; 86.5%, 43.3% and 67.2%; 91.9%, 40.0% and 68.7%; and 64.9%, 73.3% and 83.6%, respectively, and the combined specificity was 92.9%. There was no statistical difference in λ between the two groups (p > 0.05).
CONCLUSION: The quantitative parameters obtained in the pre-contrast dual-energy spectral CT imaging may be used to differentiate between parapelvic cyst and HNC. Advances in knowledge: The pre-contrast dual-energy spectral CT scans may be used to screen parapelvic cysts for patients who are asymptomatic, thereby avoiding contrast-enhanced CT or CT urography examination for these patients to reduce ionizing radiation dose and contrast dose.