高强度聚焦超声治疗子宫腺肌病:T2加权图像磁共振成像特征与疗效的关系

High intensity focused ultrasound treatment of adenomyosis: The relationship between the features of magnetic resonance imaging on T2 weighted images and the therapeutic efficacy.
PubMed 文献 · Eur J Radiol · 2017-02-02

研究纳入2011年1月至2015年11月接受高强度聚焦超声治疗的428例子宫腺肌病患者,按T2WI信号强度和亮斑数量分组,比较非灌注体积比、能量效率因子、治疗时间、超声辐照时间和不良反应。结果示低信号与等信号组间无显著差异,多亮斑组超声辐照时间和能量效率因子显著高于少亮斑组,非灌注体积比显著低于少亮斑组,两组不良反应无显著差异。作者认为疗效与T2WI信号强度无关,亮斑数量可作为选择患者的预测因素。

要点

  • T2WI上子宫腺肌病病灶信号强度(低信号与等信号)与HIFU治疗参数及结果无显著差异。
  • T2WI亮斑数量多者超声辐照时间和能量效率因子显著高于亮斑少者,非灌注体积比显著更低。
  • 亮斑数量可作为预测HIFU治疗反应的因素,帮助选择患者。

核心结论

  • 子宫腺肌病病灶对HIFU治疗的反应与T2WI信号强度无关,但T2WI上高信号亮斑数量可作为预测因素帮助选择HIFU治疗患者。

研究设计与样本

  • 研究纳入2011年1月至2015年11月428例有症状的子宫腺肌病患者接受HIFU治疗,根据T2WI病灶信号强度和亮斑数量分组,HIFU消融后次日行增强MRI,比较非灌注体积比、能量效率因子、治疗时间、超声辐照时间和不良反应。

关键影像表现/征象

  • T2WI上子宫腺肌病病灶表现为低信号或等信号,并可按高信号亮斑数量分为多亮斑组和少亮斑组。
  • HIFU消融后次日增强MRI显示病灶非灌注体积,用于计算非灌注体积比。

诊断标准与关键数值

  • 低信号病灶组与等信号病灶组之间HIFU治疗设置和结果无显著差异(P>0.05)。
  • 多亮斑组超声辐照时间和能量效率因子显著高于少亮斑组。
  • 多亮斑组非灌注体积比显著低于少亮斑组(P<0.05)。
  • 两组不良反应发生率无显著差异。

临床应用与阅片要点

  • 阅片时需在T2WI上评估子宫腺肌病病灶的信号强度并计数高信号亮斑数量。
  • 亮斑数量多的病灶HIFU治疗时超声辐照时间和能量效率因子更高、非灌注体积比更低,可作为选择HIFU治疗患者的预测因素。
  • 信号强度(低信号与等信号)与HIFU治疗参数及结果无显著差异,不是选择患者的依据。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the relationship between the features of magnetic resonance imaging (MRI) on T2 weighted images (T2WI) and the therapeutic efficacy of high intensity focused ultrasound (HIFU) on adenomyosis.

MATERIALS AND METHODS: From January 2011 to November 2015, four hundred and twenty-eight patients with symptomatic adenomyosis were treated with HIFU. Based on the signal intensity and the number of hyperintense foci in the adenomyotic lesions on T2WI, the patients were classified into groups. The day after HIFU ablation patients underwent contrast-enhanced MRI and a comparison was made of non-perfused volume (NPV) ratio, energy efficiency factor (EEF), treatment time, sonication time, and adverse effects.

RESULTS: No significant difference in terms of HIFU treatment settings and results was observed between the group of patients with hypointense adenomyotic lesions and the group with isointense adenomyotic lesions (P>0.05). However, the sonication time and EEF were significantly higher in the group with multiple hyperintense foci compared to the group with few hyperintense foci. The NPV ratio achieved in the lesions with multiple hyperintenese foci was significantly lower than that in the lesions with few hyperintense foci (P<0.05). No significant difference was observed in the rate of adverse effects between the two groups.

CONCLUSIONS: Based on our results, the response of the adenomyotic lesions to HIFU treatment is not related to the signal intensity of adenomyotic lesions on T2WI. However, the number of the high signal intensity foci in the adenomyotic lesions on T2WI can be considered as a predictive factor to help select patients for HIFU treatment.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Gong C, Setzen R, Liu Z, et al. High intensity focused ultrasound treatment of adenomyosis: The relationship between the features of magnetic resonance imaging on T2 weighted images and the therapeutic efficacy. Eur J Radiol. 2017. PMID: 28267526. doi:10.1016/j.ejrad.2017.02.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。