三维旋转血管造影的CT重建与MRI融合在儿童脑血管病变评估中的应用
回顾性纳入16例儿童(9.6±3.8岁)共18次3DRA-CT检查,评估3DRA-CT及MRI融合的可行性与临床价值。所有病例技术成功并提供对治疗决策有用的信息;非减影与减影3DRA辐射剂量分别为对应双平面2D-DSA的5.9%和132.2%。结论认为3DRA-CT是评估儿童脑血管病变的有用辅助手段,与MRI融合可进一步增强诊断信息。
要点
- 3DRA数据可重建为类CT图像,生成多平面重组与最大密度投影图像。
- 3DRA-CT与3D T1 MRI融合可精确显示神经血管关系。
- 非减影3DRA辐射剂量低于对应双平面2D-DSA,减影3DRA则高于对应2D-DSA。
核心结论
- 低辐射剂量、高空间分辨率和多平面重组能力使3DRA-CT成为评估儿童脑血管病变的有用辅助手段。
- 将3DRA-CT数据与MRI融合可进一步增强诊断信息。
研究设计与样本
- 回顾性研究,纳入16例儿童共18次3DRA-CT检查,年龄9.6±3.8岁(范围2-16岁),研究时间跨度为1年。
- 先行双平面2D数字减影血管造影(DSA),随后行5秒3DRA,选择性血管注射,伴或不伴减影。
- 图像重建为CT层面,后处理生成多平面重组(MPR)和最大密度投影(MIP)图像;与3D T1 MRI图像融合。
- 提取定量辐射指标,与整个检查及对应双平面2D-DSA采集的辐射剂量进行比较。
关键影像表现/征象
- 3DRA-CT生成的MPR和MIP图像可用于显示神经血管关系。
- 3DRA-CT与3D T1 MRI融合可精确显示神经血管关系。
诊断标准与关键数值
- 非减影3DRA采集的辐射剂量为对应双平面2D-DSA采集平均辐射剂量的5.9%。
- 减影3DRA采集的辐射剂量为对应双平面2D-DSA采集平均辐射剂量的132.2%。
- 非减影3DRA采集占总手术剂量的1.2%。
- 减影3DRA采集占总手术剂量的12.5%。
- 全部18例3DRA操作及MRI融合技术成功,并提供与治疗决策相关的临床有用信息。
临床应用与阅片要点
- 原文结论认为3DRA-CT是评估儿童脑血管病变的有用辅助手段。
- 原文结论认为3DRA-CT与MRI融合可进一步增强诊断信息。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Complex neurovascular lesions in children require precise anatomic understanding for treatment planning. Although 3DRA is commonly employed for volumetric reformation in neurointerventional procedures, the ability to reconstruct this data into CT-like images (3DRA-CT) is not widely utilized. This study demonstrates the feasibility and usefulness of 3DRA-CT and subsequent MRI fusion for problem solving in pediatric neuroangiography.
METHODS: This retrospective study includes 18 3DRA-CT studies in 16 children (age 9.6 ± 3.8 years, range 2-16 years) over 1 year. After biplane 2D-digital subtraction angiography (DSA), 5-second 3DRA was performed with selective vessel injection either with or without subtraction. Images were reconstructed into CT sections which were post-processed to generate multiplanar reformation (MPR) and maximum intensity projection (MIP) images. Fusion was performed with 3D T1 MRI images to precisely demonstrate neurovascular relationships. Quantitative radiation metrics were extracted and compared against those for the entire examination and for corresponding biplane 2D-DSA acquisitions.
RESULTS: In all 18 cases, the 3DRA procedure and MRI fusion were technically successful and provided clinically useful information relevant to management. The unsubtracted and subtracted 3DRA acquisitions were measured to deliver 5.9 and 132.2%, respectively, of the mean radiation dose of corresponding biplane 2D-DSA acquisitions and contributed 1.2 and 12.5%, respectively, to the total procedure dose.
CONCLUSION: Lower radiation doses, high spatial resolution, and multiplanar reformatting capability make 3DRA-CT a useful adjunct to evaluate neurovascular lesions in children. Fusing 3DRA-CT data with MRI is an additional capability that can further enhance diagnostic information.
引用
- Muthusami P, Shkumat N, Rea V, et al. CT reconstruction and MRI fusion of 3D rotational angiography in the evaluation of pediatric cerebrovascular lesions. Neuroradiology. 2017. PMID: 28349170. doi:10.1007/s00234-017-1818-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。