文献速递儿科影像腹部MR

磁共振小肠造影在儿童克罗恩病炎症检测中具有良好的观察者间一致性和诊断准确性

Magnetic resonance enterography has good inter-rater agreement and diagnostic accuracy for detecting inflammation in pediatric Crohn disease.
PubMed 文献 · Pediatr Radiol · 2017-03-10

本研究为单中心横断面研究,由两名独立放射科医生对48例确诊克罗恩病儿童(66%男性,中位年龄15.5岁)的MRE进行独立评估,分析15个MRE炎症征象在10个胃肠解剖节段的观察者间一致性及与wPCDAI和CRP的相关性及诊断准确性。结果显示肠壁强化、T2高信号、肠壁增厚和DWI高信号最常见;动力减低和DWI高信号的观察者间一致性最佳(kappa≥0.64);溃疡、肠壁强化、肠壁增厚、T2高信号和DWI高信号的AUC最高(≥0.75)。

要点

  • 儿童克罗恩病MRE中,动力减低和肠壁DWI高信号的观察者间一致性最佳(kappa≥0.64)
  • 溃疡、肠壁强化、肠壁增厚、T2高信号和DWI高信号的AUC最高(≥0.75)
  • MRE征象与wPCDAI的相关性高于与CRP的相关性

核心结论

  • 部分MRE征象在儿童克罗恩病炎症检测中具有良好观察者间一致性和AUC。

研究设计与样本

  • 单中心横断面研究,纳入48例确诊克罗恩病儿童(66%男性,中位年龄15.5岁),由两名独立放射科医生评估MRE,参考标准为wPCDAI和CRP。

关键影像表现/征象

  • 肠壁强化、肠壁T2高信号、肠壁增厚和肠壁DWI高信号是最常被识别的征象。
  • 动力减低和肠壁DWI高信号的观察者间一致性最佳(kappa≥0.64)。

诊断标准与关键数值

  • 以wPCDAI≥12.5且CRP≥5定义活动性炎症,计算每个加权MRE征象的AUC。
  • 溃疡、肠壁强化、肠壁增厚、肠壁T2高信号和肠壁DWI高信号的AUC最高(≥0.75)。
  • MRE征象与wPCDAI的相关性高于与CRP的相关性。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Magnetic resonance enterography (MRE) is increasingly relied upon for noninvasive assessment of intestinal inflammation in Crohn disease. However very few studies have examined the diagnostic accuracy of individual MRE signs in children.

OBJECTIVE: We have created an MR-based multi-item measure of intestinal inflammation in children with Crohn disease - the Pediatric Inflammatory Crohn's MRE Index (PICMI). To inform item selection for this instrument, we explored the inter-rater agreement and diagnostic accuracy of individual MRE signs of inflammation in pediatric Crohn disease and compared our findings with the reference standards of the weighted Pediatric Crohn's Disease Activity Index (wPCDAI) and C-reactive protein (CRP).

MATERIALS AND METHODS: In this cross-sectional single-center study, MRE studies in 48 children with diagnosed Crohn disease (66% male, median age 15.5 years) were reviewed by two independent radiologists for the presence of 15 MRE signs of inflammation. Using kappa statistics we explored inter-rater agreement for each MRE sign across 10 anatomical segments of the gastrointestinal tract. We correlated MRE signs with the reference standards using correlation coefficients. Radiologists measured the length of inflamed bowel in each segment of the gastrointestinal tract. In each segment, MRE signs were scored as either binary (0-absent, 1-present), or ordinal (0-absent, 1-mild, 2-marked). These segmental scores were weighted by the length of involved bowel and were summed to produce a weighted score per patient for each MRE sign. Using a combination of wPCDAI≥12.5 and CRP≥5 to define active inflammation, we calculated area under the receiver operating characteristic curve (AUC) for each weighted MRE sign.

RESULTS: Bowel wall enhancement, wall T2 hyperintensity, wall thickening and wall diffusion-weighted imaging (DWI) hyperintensity were most commonly identified. Inter-rater agreement was best for decreased motility and wall DWI hyperintensity (kappa≥0.64). Correlation between MRE signs and wPCDAI was higher than with CRP. AUC was highest (≥0.75) for ulcers, wall enhancement, wall thickening, wall T2 hyperintensity and wall DWI hyperintensity.

CONCLUSION: Some MRE signs had good inter-rater agreement and AUC for detection of inflammation in children with Crohn disease.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Church PC, Greer MC, Cytter-Kuint R, et al. Magnetic resonance enterography has good inter-rater agreement and diagnostic accuracy for detecting inflammation in pediatric Crohn disease. Pediatr Radiol. 2017. PMID: 28283726. doi:10.1007/s00247-017-3790-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。